DEVICE: VCARE LARGE (30653405061810)
Device Identifier (DI) Information
VCARE LARGE
60-6085-202
Not in Commercial Distribution
60-6085-202
Conmed Corporation
60-6085-202
Not in Commercial Distribution
60-6085-202
Conmed Corporation
VCARE LARGE UTERINE MANIPULATOR
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
58051 | Uterine manipulator, single-use |
A sterile, hand-held manual surgical instrument designed to atraumatically mechanically manipulate the position of the uterus during a gynaecological intervention (e.g., laparoscopy) to enable uterine control and improved visibility of the pelvic anatomy, as well as for chromotubation. The device typically consists of a long shaft with an inflatable balloon at the distal end which is transcervically placed inside the uterus and inflated, via a connected syringe (sometimes included), with sterile saline or air; once inflated, the operator can manipulate the uterus. Deflation is a reverse of the inflation process. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LKF | CANNULA, MANIPULATOR/INJECTOR, UTERINE |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K071907 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 10 and 32 Degrees Celsius |
Storage Environment Temperature: between 50 and 90 Degrees Fahrenheit |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
874604fc-0bdf-481c-bb82-2b346702e352
March 07, 2023
5
September 24, 2016
March 07, 2023
5
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
20653405061813 | 8 | 30653405061810 | 2023-03-07 | Not in Commercial Distribution | BOX |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
00653405061819
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)237-0169
CUSTOMER_SERVICE@CONMED.COM
CUSTOMER_SERVICE@CONMED.COM