DEVICE: Left Heart Sump 90 Degrees (B0662010890000)

Device Identifier (DI) Information

Left Heart Sump 90 Degrees
201089-000
In Commercial Distribution
201089-000
NOVOSCI CORP.
B0662010890000
HIBCC

1
938289980 *Terms of Use
A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
No
No
No
No
No

GMDN

[?]

GMDN Names and Definitions: © Copyright GMDN Agency 2015. Reproduced with Permission from the GMDN Agency.

GMDN Preferred Term Name GMDN Definition
Surgical irrigation/aspiration handpiece, single-use A hand-held device designed to regulate and direct a stream of pressurized fluid (e.g., sterile water or saline) and as an alternative provide aspiration (suction), to a surgical site, for the purpose of irrigating and clearing debris from the field of intervention. It is fitted with a long syringe-like nozzle that is activated by the user, typically through a push-type control(s). This device is typically a component of a surgical irrigation/aspiration system used for ENT or neurological surgery. This is a single-use device.
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K801392 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

130b9e54-669b-4ddf-b5df-39ad4da1121d
July 06, 2018
3
September 26, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
B0662010890006 100 B0662010890000 In Commercial Distribution Case
B0662010890005 75 B0662010890000 In Commercial Distribution Partial Case
B0662010890004 50 B0662010890000 In Commercial Distribution Partial Case
B0662010890003 25 B0662010890000 In Commercial Distribution Inner Carton
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
No
Yes
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE