DEVICE: CONNECTOR, 1/4" PERFUSION ADAPTER (B066301009NS1)

Device Identifier (DI) Information

CONNECTOR, 1/4" PERFUSION ADAPTER
301009NS
In Commercial Distribution
301009NS
NOVOSCI CORP.
B066301009NS1
HIBCC

500
938289980 *Terms of Use
A sterile plastic device designed to join two or more tubes of a cardiopulmonary bypass system circuit, typically to create an extension or shunt; it may also be used to connect ancillary disposable devices (e.g., temperature probe). It typically has a Y-shape or straight design and is profiled at its ends to create leak-proof connections. This is a single-use device.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
64466 Non-ISO80369-standardized small-bore linear connector, single-use
A small, non-powered, noninvasive, small-bore, tubular, two-way/linear connector with connections at each end (typically barbed, bayonet, conical, threaded and/or non-Luer-slip) which are not designed according to ISO 80369 (standard for small-bore connectors for liquids and gases) intended to connect two luminal devices (e.g., catheter, tubing, container) with each other. It may have a straight or elbow shape; it does not have a Luer connection(s) (neither lock nor slip), and does not incorporate a filter, valve, clamp, tubing nor puncturing component, and is not a dedicated gas-line connector. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DTL Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K801405 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

29bd5bd5-52f2-4da9-ac12-cc6e1159bcc8
July 13, 2023
3
October 08, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
B066301009NS3 1000 B066301009NS1 In Commercial Distribution CASE
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: B066301009NS0 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
800-854-0567
info@novosci.com
CLOSE