DEVICE: LINE, VENOUS 1/2" X 3/32" X 84" (B0663110030000)

Device Identifier (DI) Information

LINE, VENOUS 1/2" X 3/32" X 84"
311003-000
In Commercial Distribution
311003-000
NOVOSCI CORP.
B0663110030000
HIBCC

1
938289980 *Terms of Use
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35441 Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K801401 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d07ce71f-32cd-4442-9fbe-484246e04f05
July 07, 2023
4
October 09, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
B0663110030003 3 B0663110030000 In Commercial Distribution CASE
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
800-854-0567
info@novosci.com
CLOSE