DEVICE: BIPOLAR JENSEN BAYONET FORCEPS (B099270089150)

Device Identifier (DI) Information

BIPOLAR JENSEN BAYONET FORCEPS
2700-8915
Not in Commercial Distribution

SONTEC INSTRUMENTS, INC.
B099270089150
HIBCC
June 22, 2018
1
040729840 *Terms of Use
BIPOLAR JENSEN BAYONET FORCEPS FLAT HANDLE INSULATED
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
32684 Endoscopic electrosurgical handpiece/electrode, bipolar, reusable
An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery; it may in addition be intended for open surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps, rigid probe with controls). This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, Cutting & Coagulation & Accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K101080 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
Dry Heat Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 7 Inch
Device Size Text, specify: 1.5mm Tip
CLOSE

Device Record Status

0e89c660-3854-43b1-9e53-3beec16a41d8
July 06, 2018
7
August 19, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
800-821-7496
info@sontecinstruments.com
CLOSE