DEVICE: Emory Cardiac Toolbox (B133ECTB422112080)
Device Identifier (DI) Information
Emory Cardiac Toolbox
4.27720.29473
In Commercial Distribution
SYNTERMED INCORPORATED
4.27720.29473
In Commercial Distribution
SYNTERMED INCORPORATED
The Emory Cardiac Toolbox™ 4.0 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the .NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
60724 | Multidisciplinary medical image management software |
A software application intended to be used to receive, collect, store, and display a broad range of medical imaging and/or video data, and to distribute the data within or between healthcare facilities to facilitate data analysis, organization, reporting, and sharing (e.g., teaching); it might be designed for holographic viewing of three-dimensional (3-D) images in conjunction with an appropriate headset or for real-time communication of diagnostic/surgical images, and might also enable the control of light settings of a device (e.g., microscope) for image acquisition.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KPS | System, Tomography, Computed, Emission |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K123646 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
ccf4c7fd-9578-4df5-b2bf-4dfc82661fe1
January 10, 2023
2
December 28, 2021
January 10, 2023
2
December 28, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined