DEVICE: STARband® (B151761PA0)

Device Identifier (DI) Information

STARband®
761PA
In Commercial Distribution
761PA
ORTHOMERICA PRODUCTS, INC.
B151761PA0
HIBCC

1
604405373 *Terms of Use
The STARband® is a patient specific cranial orthosis that redirects the head growth to improve proportion and symmetry. It is intended for use on infants from 3 to 18 months of age, with moderate-to-severe non-synostotic positional head shape deformities, including infants with plagiocephalic-, brachycephalic- and scaphocephalic-shaped heads by applying mild pressure to prominent regions of the infant's cranium in order to improve cranial symmetry and/or shape. This device is also indicated for adjunctive use for infants from 3 to 18 months of age whose synostosis has been surgically corrected, but who still have moderate-to-severe cranial deformities including plagiocephalic-, brachycephalic- and scaphocephalic-shaped heads. The STARband® is made with an outer copolymer plastic shell and an inner liner made of pelite polyethylene foam or Aliplast foam (closed cell polyethylene). It utilizes a side opening design and is held in place by a Velcro® strap across the side opening.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
62265 Cranial orthosis
A custom-made helmet-like device intended to be worn on the head of an infant with an abnormal head shape (e.g., due to plagiocephaly, brachycephaly, scaphocephaly), or after craniosynostosis repair surgery, to apply pressure to the cranium and improve cranial symmetry/shape during growth over a period of months. It is made of durable materials (e.g., plastic, solid foam) and is designed with patient-specific characteristics (e.g., size, shape) based on head measurements (e.g., clinical pictures, 3-D scans, casts). It is typically worn during daily activities and sleep. This is a single-patient device that can be reapplied during the treatment period (reusable) before being discarded.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OAN Orthosis, Cranial, Laser Scan
MVA Orthosis, Cranial
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

e2fe4c20-f2b8-4986-b76b-f95b3a2945aa
March 29, 2018
2
August 23, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
18004466770
custserv@orthomerica.com