DEVICE: COUNTER TOP/WALL MOUNT BLANKET/FLUID WARMING CABINET (B286FHCSWC1518TLGDEMO1)

Device Identifier (DI) Information

COUNTER TOP/WALL MOUNT BLANKET/FLUID WARMING CABINET
FHCSWC1518-TL-G-DEMO
In Commercial Distribution
FHCSWC1518-TL-G-DEMO
M.A.C. MEDICAL INC.
B286FHCSWC1518TLGDEMO1
HIBCC

1
188660844 *Terms of Use
Overall size 18”W x 15.5”D x 22”T. 1.4 Cubic ft. storage Chamber I.D. 14”W x 13"D x 13”T Temperature Range: 90-135 F Accuracy +/- 1 degrees F Digital control. Glass door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Foot levelers Electrical: 120V, 3.5 Amp, 50/60 Hz. .39kw/hr, 1332 btu/hr.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
55829 Blanket warming cabinet, dry-heat
A mains electricity (AC-powered) device designed to warm blankets with hot dry air. It is typically a high capacity (e.g., 0.2 to 0.5 m3) unit with appropriate perforated shelves for blanket positioning, avoiding contact with very hot surfaces to prevent scorching. Hot dry air is usually circulated to heat blankets in a temperature range from 30 to 90? C (90 to 200? F).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LHC Warmer, Irrigation Solution
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K080609 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

f5c81703-17cf-4287-8b74-e2dd25d9c85b
July 06, 2018
3
July 28, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
(877) 828-9975
info@macmedical.com
CLOSE