DEVICE: SINGLE CHAMBER WARMING CABINET GLASS DOOR (B286FHCSWC1824TLGDB1)

Device Identifier (DI) Information

SINGLE CHAMBER WARMING CABINET GLASS DOOR
FHCSWC1824-TL-G-D-B
In Commercial Distribution
FHCSWC1824-TL-G-D-B
M.A.C. MEDICAL INC.
B286FHCSWC1824TLGDB1
HIBCC

1
188660844 *Terms of Use
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Data Logger Foot levelers 2 Pull-out bins Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
55829 Blanket warming cabinet, dry-heat
A mains electricity (AC-powered) device designed to warm blankets with hot dry air. It is typically a high capacity (e.g., 0.2 to 0.5 m3) unit with appropriate perforated shelves for blanket positioning, avoiding contact with very hot surfaces to prevent scorching. Hot dry air is usually circulated to heat blankets in a temperature range from 30 to 90? C (90 to 200? F).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LHC Warmer, Irrigation Solution
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K080609 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

81e77885-aad6-4eda-a1e1-a09e7a87bc94
July 06, 2018
3
July 28, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
(877) 828-9975
info@macmedical.com