DEVICE: Osseoflex SB Steerable Balloon (10ga/2ml) (B330OF02220)

Device Identifier (DI) Information

Osseoflex SB Steerable Balloon (10ga/2ml)
OF-0222
In Commercial Distribution

OSSEON LLC
B330OF02220
HIBCC

1
079316474 *Terms of Use
The Osseoflex® SB is designed for use in balloon kyphoplasty. The balloon serves to create a cavity in the vertebral body, thereby reducing the fracture while still while still allowing for cement interdigitation. The balloon catheter is the functional part of the device that creates a cavity and reduces the fracture. The balloon catheter provides a conduit through which the physician can inflate the balloon at the distal end of the catheter. After the bone is disrupted, PMMA is injected through an Osseoflex® SN steerable needle to fill the previously created void(s). An access channel is required for the Osseoflex® SB placement. The Osseoflex® SB device does not create an access channel; the Osseoflex® SB is designed to follow a pre-existing channel created by an access channel device. If the balloon has an Articulating Stylet inserted it enables the steerable feature of the balloon. The articulating or steering feature of the device assists the clinician in directing the device through the pre-existing channel. The Osseoflex® SB actuation knob can be turned clockwise to aid in directing the distal portion of the device. Turning the actuation knob counter-clockwise will relax the device and allow the device to be returned to it's start position. The device should be manipulated only while under fluoroscopic observation with radiographic equipment that provides high quality images.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47021 Inflatable bone tamp
A catheter-like device with an inflatable balloon at the distal end used for the reduction of fractures and/or creation of a void in cancellous bone [e.g., in the spine for a vertebral compression fracture (VCF), hand, tibia, radius, and calcaneus]. It is commonly used for kyphoplasty, which involves its insertion into a patient's back to reduce a vertebral body fracture by compression of cancellous bone and/or movement of the endplates as the balloon is inflated. After the device is removed, orthopaedic bone cement is introduced into the created void to stabilize the vertebra. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
NDN Cement, Bone, Vertebroplasty
HRX Arthroscope
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Needle Gauge: 11 Gauge
Total Volume: 2 Milliliter
CLOSE

Device Record Status

e85e980e-d938-4d5a-a70b-aa98faf7c0cd
March 29, 2018
2
September 09, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
(877) 567-7366