DEVICE: LifeSignals (B353LP12501)
Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to
GUDIDSupport@fda.hhs.gov.
Device Identifier (DI) Information
LifeSignals
LP1250
Not in Commercial Distribution
Lifesignals, Inc.
LP1250
Not in Commercial Distribution
Lifesignals, Inc.
Wearable Biosensor - ECG Remote Monitoring Biosensor Patch
Device Characteristics
| MR Unsafe | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 35162 | Electrocardiographic ambulatory recorder |
An electrically-powered, noninvasive device designed to be worn by a patient during daily activities for 24-hour recording of the electrocardiographic signals of the heart, for the diagnosis of cardiac disorders (e.g., arrhythmias). The recorded measurements can be downloaded and analysed at a medical facility, typically using a computer with a dedicated software. Otherwise known as a Holter monitor, the device typically incorporates display and controls, and may include surface electrodes, lead wires and accessories intended for attachment/removal (e.g., wipes, adhesive remover).
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| DRG | Transmitters And Receivers, Physiological Signal, Radiofrequency |
| MWJ | Electrocardiograph, Ambulatory (Without Analysis) |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Special Storage Condition, Specify: For long-term storage of more than 30 days, maintain between 5 and 27 Degrees Celsius |
| Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity |
| Storage Environment Temperature: between 0 and 45 Degrees Celsius |
| Handling Environment Humidity: between 10 and 90 Percent (%) Relative Humidity |
| Handling Environment Temperature: between 0 and 45 Degrees Celsius |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
710fb91c-8850-4a2e-b412-d8d192e63152
November 30, 2023
4
August 11, 2020
November 30, 2023
4
August 11, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| B353LP12502 | 25 | B353LP12501 | 2023-11-01 | Not in Commercial Distribution | Small BOx |
| B353LP12503 | 8 | B353LP12502 | 2023-11-01 | Not in Commercial Distribution | Big Box |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
510.770.6412
saravanan@lifesignals.com
saravanan@lifesignals.com