DEVICE: Distal Fibula Plating System (B471126600110)
Device Identifier (DI) Information
Distal Fibula Plating System
12660011
In Commercial Distribution
GRAMERCY EXTREMITY ORTHOPEDICS LLC
12660011
In Commercial Distribution
GRAMERCY EXTREMITY ORTHOPEDICS LLC
Distal Fibula Plate Deep Syndesmosis Fixation Holes, 11-Hole
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46647 | Orthopaedic fixation plate, non-bioabsorbable |
A non-bioabsorbable, non-customized, firm, implantable sheet intended to stabilize a fractured orthopaedic bone (excluding craniofacial and spinal) to treat a traumatic/pathological fracture, to fuse a joint (arthrodesis) and/or as part of an osteotomy. Typically attached to a bone of a limb, rib, sternum, or pelvis, it is designed to be fixed in place with screws; it does not incorporate a sleeve or blade. Instruments intended to facilitate implantation, or fixation implants (i.e., bone screws), may be included with the plate.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HRS | Plate, fixation, bone |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -10 and 55 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
f38273f7-7ed7-4c7d-a11f-766c01eab35f
September 18, 2023
2
January 10, 2022
September 18, 2023
2
January 10, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(855)436-2278
GEOSupportCenter@gramercyortho.com
GEOSupportCenter@gramercyortho.com