DEVICE: SPEAC System Assy, Mini Monitor, US (B481SPC15900570)

Device Identifier (DI) Information

SPEAC System Assy, Mini Monitor, US
SPC15
In Commercial Distribution
SPC15-90057
BRAIN SENTINEL, INC.
B481SPC15900570
HIBCC

1
969967764 *Terms of Use
The SPEAC® System, formerly known as the Brain Sentinel® Monitoring and Alerting System (Predicate), is a physiological, surface electromyography (sEMG) monitor with or without alarms that records and stores data for review by a physician for characterization of seizure events. Page 2 of 13 The System records sEMG data at 1,000 Hz and distributes physiological data. Data can be analyzed with an algorithm using the default threshold or by a modified threshold ordered by the physician. The sEMG monitor is worn unilaterally on the belly of the patient’s biceps and it analyzes for sEMG GTC seizures and provide local, remote, audible, and visual seizure alarms when a GTC Seizure pattern that may be associated with such seizures that are detected. The SPEAC System provides sEMG recordings and audio data to physicians (or other trained healthcare professionals) for post-hoc review so that they may quantify and qualify the types of seizure events that their patients experience. Every 24 hours, the sEMG monitor is removed from the patient and replaced with the second sEMG Monitor on the opposite arm of the patient. The sEMG that is removed after 24-hours is then attached to a Base Station. By connecting the sEMG Monitor to the Base Station, the monitor charges and the recorded data is downloaded to the Base Station. The recorded data is then automatically uploaded to Brain Sentinel’s cloud-based storage unit, Data Distribution System (DDS), where they await review by a physician. All patient data is cyber-secured within Microsoft Azure which is FedRAMP certified. Below, Tables 1 and 2 list the functional and operational outputs designed to provide feedback to the patient and caregiver.
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61288 Home seizure monitoring system
An assembly of devices intended to detect and record a seizure by continuous measurement of one or more physical/physiological parameters (e.g., body motion, electrical activity of the heart or skeletal muscles) in a patient with epilepsy during daily activities and/or sleep in the home; some types may also be used in clinical settings. It typically consists of a mains electricity (AC-powered) central monitor that wirelessly receives, records, and displays the data, and one or more battery-powered body-worn sensor(s); it may have alarms and data may be transmitted to a cloud-based storage, server or mobile device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
POS Physiological Signal Based Seizure Monitoring System
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 5 and 35 Degrees Celsius
Handling Environment Temperature: between 5 and 35 Degrees Celsius
Storage Environment Humidity: between 45 and 85 Percent (%) Relative Humidity
Handling Environment Humidity: between 45 and 85 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

5643134f-b135-4d81-bc0e-18bc3972ceaa
September 12, 2019
1
September 04, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE