DEVICE: Instrumentation Difra (B51617485)

Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to GUDIDSupport@fda.hhs.gov.

Device Identifier (DI) Information

Instrumentation Difra
AirStar 2.0
In Commercial Distribution
17485
Instrumentation Difra SA
B51617485
HIBCC

1
370173410 *Terms of Use
The air caloric stimulator is a device that delivers a stream of air to the ear canal at controlled rates of flow and temperature and that is intended for vestibular function testing of a patient's body balance system. The vestibular stimulation of the semicircular canals produces involuntary eye movements. The handle is equipped with an otoscope head where a disposable ear tips can be fixed for easy management of hygiene. The otoscope handle provides also a magnifying glass and integrated light to inspect the ear canal and the tympanic membrane without obstructing the stimulation. By default, temperature values are 27°C, 30°C, 44°C and 47°C. Five stimulation times are available: 40, 60, 80,100 and 120s Warm air caloric stimulator Minimal temperature reachable: 5°C over the ambient temperature Maximal temperature reachable: 48°C Air flow: fixed, from 10 to 13l/min, without ear tip Timer Intended user: Qualified users, ENT doctors, audiologist, nurses and medical staff trained to the device and to the caloric testing process.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
Yes
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
34891 Diagnostic caloric vestibular stimulation system
An assembly of devices intended to evaluate a patient’s vestibular function through the application of heat and/or cold stimuli in the form of a stream of air or water into the ear canal, whereby involuntary horizontal eye movements (nystagmus) are produced and measured using a nystagmograph. The procedure may also be referred to as caloric reflex test, and is typically used for assessing a patient's balance system and/or to test for brainstem death. It typically consists of an irrigation system that includes a pump, valves, heaters and regulators to control the rate of flow and temperature of the medium. This device is typically used in an ear/nose/throat (ENT) department.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KHH Stimulator, Caloric-Air
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 5 and 35 Degrees Celsius
Storage Environment Temperature: between 5 and 55 Degrees Celsius
Storage Environment Humidity: between 30 and 90 Percent (%) Relative Humidity
Handling Environment Humidity: between 30 and 90 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Depth: 34.5 Centimeter
Length: 31 Centimeter
Height: 11.5 Centimeter
Weight: 5 Kilogram
CLOSE

Device Record Status

f41d105f-d882-42e9-9b08-a85dea04dd96
November 19, 2020
2
September 17, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
260.436.1436
dbscherer@gmail.com
CLOSE