DEVICE: Accula Programming Cassette (B540D20010)

Device Identifier (DI) Information

Accula Programming Cassette
D2001
In Commercial Distribution
D2001
MESA BIOTECH, INC.
B540D20010
HIBCC

1
056865474 *Terms of Use
The Programming Cassette is an accessory to the Accula Dock and facilitates reprogramming of the Dock’s embedded firmware. When firmware updates are needed, the firmware will be stored onto Programming Cassettes and sent to end users, who will load the Programming Cassette into their Dock and re-program its firmware
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
62875 Thermal cycler nucleic acid amplification analyser IVD, point-of-care
A portable, electrically-powered instrument intended to be used by health professionals at the point-of-care to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling (i.e., thermal cycling) to replicate a product [i.e., a polymerase chain reaction (PCR)]. Amplified product is detected and/or identified using oligonucleotide markers as it is produced (i.e., in real-time) or at the end-point. The analyser may also isolate, extract and/or prepare nucleic acid from the clinical specimen and/or culture isolate prior to amplification.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QJR Reagents, 2019-Novel Coronavirus Nucleic Acid
OZE Influenza A And Influenza B Multiplex Nucleic Acid Assay
OCC Respiratory Virus Panel Nucleic Acid Assay System
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 15 and 30 Degrees Celsius
Handling Environment Temperature: between 59 and 86 Degrees Fahrenheit
Handling Environment Humidity: between 20 and 80 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

ec9b032d-3f1f-458d-ac69-602c3e6d9ccb
July 07, 2020
2
June 08, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
858-800-4929
info@mesabiotech.com