DEVICE: Vios Monitoring System Pulse Oximetry Sensor (B595L2050R0)
Device Identifier (DI) Information
Vios Monitoring System Pulse Oximetry Sensor
L2050R Pulse Oximetry Sensor
In Commercial Distribution
L2050R
MURATA VIOS, INC.
L2050R Pulse Oximetry Sensor
In Commercial Distribution
L2050R
MURATA VIOS, INC.
The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure (NIBP) continuously and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters.
The non-invasive blood pressure tracking is based on Pulse Arrival Time (PAT) which is obtained utilizing ECG and PPG signals, following a calibration process using an FDA-cleared oscillometric blood pressure monitor. This feature is not intended for use in critical care environment.
VMS can also generate alerts when cardiac arrhythmias (Tachycardia, Bradycardia, Asystole, Ventricular Tachycardia/Ventricular Fibrillation and Atrial Fibrillation/Atrial Flutter) are detected.
The ECG rhythm analysis is intended for use by medically qualified professionals in the identification of arrhythmia events and to aid in clinical review of arrhythmia and medical interventions.
The VMS Adapter and Chest Sensor are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients.
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
37808 | Pulse oximeter probe, reusable |
A photoelectric device designed to be applied externally to a body site (e.g., fingertip, ear lobe, bridge of nose, toe, or bridge of the foot) for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using signals produced by a light-emitting diode (LED) and received by a photodetector. The signals are subsequently transmitted to an oximeter/monitor (not included) which measures and displays the SpO2. This is a reusable device.
|
Active | false |
47582 | Pulse Co-oximeter probe, reusable |
A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically several other related parameters such as haemoglobin oxygen saturation (SpO2), methaemoglobin saturation (SpMet), haemoglobin concentration (SpHb), haematocrit, and pulse rate using light detection. Signals from the probe, produced by a light-emitting diode (LED) and a receiving detector, are used to calculate results which are digitally displayed on the Co-oximeter's computerized unit. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQA | Oximeter |
DXN | System, Measurement, Blood-Pressure, Non-Invasive |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K172586 | 000 |
K232354 | 000 |
K241728 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -40 and 70 Degrees Celsius |
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity |
Storage Environment Atmospheric Pressure: between 80 and 106 KiloPascal |
Handling Environment Temperature: between 10 and 40 Degrees Celsius |
Handling Environment Humidity: between 10 and 95 Percent (%) Relative Humidity |
Handling Environment Atmospheric Pressure: between 80 and 106 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
bc012b67-d88e-449f-8b4c-2037bdb9f5e0
March 24, 2025
6
April 27, 2020
March 24, 2025
6
April 27, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
B595L2050R1 | 50 | B595L2050R0 | In Commercial Distribution | case | |
B595L2050R2 | 8 | B595L2050R0 | In Commercial Distribution | case |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1-866-990-1434
ViosSupport@murata.com +918044324109
ViosSupport@murata.com
ViosSupport@murata.com +918044324109
ViosSupport@murata.com