DEVICE: CINA (B826CINA100)

Device Identifier (DI) Information

CINA
1.0
In Commercial Distribution

AVICENNA.AI
B826CINA100
HIBCC

1
271198112 *Terms of Use
CINA is a radiological computer-assisted triage and notification software device. The software system is based on algorithm-programmed components and is comprised of a standard off-the-shelf operating system and additional image processing applications. DICOM images are received, recorded and filtered before processing. The series are processed chronologically by running algorithms on each series to detect suspicious results of an intracranial hemorrhage (ICH) or a large vessel occlusion (LVO), then notifications on the flagged series are sent to the Worklist Application. The Worklist Application (on premise) displays the pop-up notifications of new studies with suspected findings when they come in, and provides both active and passive notifications. Active notifications are in the form of a small pop-up containing patient name, accession number and the type of suspected findings (ICH or LVO). All the non-enhanced head CT images and head CT angiographies studies received by CINA device are displayed in the worklist and those on which the algorithms have detected a suspected finding (ICH or LVO) are marked with an icon (i.e., passive notification). In addition, a compressed, small black and white image that is marked “not for diagnostic use” is displayed as a preview function. This compressed preview is meant for informational purposes only, does not contain any marking of the findings, and is not intended for primary diagnosis beyond notification. Presenting the radiologist with notification facilitates earlier triage by allowing one to prioritize images in the PACS. Thus, the suspect case receives attention earlier than would have been the case in the standard of care practice alone.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
57812 Radiology DICOM image processing application software
A software application intended to facilitate management, distribution, and/or viewing of radiological digital imaging and communications in medicine (DICOM) image data; it is not intended for pathological image interpretation (i.e., not intended to detect and localize suspected abnormalities). It may be intended to facilitate image management (e.g., viewing, communication, printing, recording/disc burning) and/or image quality manipulation and quantification (e.g., non-interpretive graphical overlays).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QAS Radiological Computer-Assisted Triage And Notification Software
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K200855 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

e41ec456-9453-48bc-84e0-9074ecf2562e
December 04, 2023
5
December 14, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE