DEVICE: CINA-CSpine (B826CINACSPINE100)

Device Identifier (DI) Information

CINA-CSpine
1.0
In Commercial Distribution

AVICENNA.AI
B826CINACSPINE100
HIBCC

1
271198112 *Terms of Use
CINA-CSpine is a radiological computer-assisted triage and notification software device. CINA-CSpine runs on a standard “off the shelf” server/workstation and consists of CSpine Image Processing Application, which can be integrated, deployed and used with the CINA Platform or other medical image communications devices. CINA-CSpine receives cervical spine CT scans identified by the CINA Platform or other medical image communications device, processes them using algorithmic methods involving execution of multiple computational steps to identify the suspected positive findings compatible with acute cervical spine fractures and generates results files to be transferred by CINA Platform or a similar medical image communications device for output to a PACS system or workstation for worklist prioritization. To identify the suspected presence of cervical fractures, the device uses a deep learning model trained end-to-end on 1,338 cases acquired from US and France, representing a distribution of fracture presentations, locations and acquisition protocols, including multiple scanner models. Additional deep learning models are used to locate the individual vertebrae to exclude images that do not conform to the expected field of view.DICOM images are received, recorded and filtered before processing. The series are processed chronologically by running algorithms on each series to detect suspected positive findings of a cervical spine fracture, then active notifications on the flagged series are sent to the worklist application. The Worklist Application displays the active notification of new studies with suspected findings when they come in. All the cervical spine CT studies which include at least 5 visible cervical vertebrae received by CINA-CSpine device are displayed in the worklist and those on which the algorithms have detected a suspected finding are marked with an icon [...].
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
57812 Radiology DICOM image processing application software
A software application intended to facilitate management, distribution, and/or viewing of radiological digital imaging and communications in medicine (DICOM) image data; it is not intended for pathological image interpretation (i.e., not intended to detect and localize suspected abnormalities). It may be intended to facilitate image management (e.g., viewing, communication, printing, recording/disc burning) and/or image quality manipulation and quantification (e.g., non-interpretive graphical overlays).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QAS Radiological Computer-Assisted Triage And Notification Software
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K240942 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

1fefa648-ccf6-4d0c-ae51-c975945b983e
October 15, 2024
1
October 07, 2024
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE