DEVICE: LungFit PH Bagging Kit (B882900050)

Device Identifier (DI) Information

LungFit PH Bagging Kit
90005
In Commercial Distribution

Beyond Air, Inc.
B882900050
HIBCC

1
080243711 *Terms of Use
The integrated Backup NO delivery system is a completely independent backup NO generating system that is separate from the main delivery system; it has its own NO generator and gas flow delivery system. Backup NO flow can be delivered to one of two different locations by using the System Selector switch located on the front panel of the LungFit PH system. When the Selector Switch is turned to “Bagging System” position, the backup NO module turns on and delivers 1 L/min of 220 ppm of NO through a separate internal NO2 filter to the Bagging System connector on the front panel of the LungFit PH system. The Bagging System connector has two tubing fittings: one for connecting to an air/oxygen source through oxygen tubing or equivalent to provide an external flow of air/oxygen and the other to connect to a manual resuscitator for manually ventilating a patient. The 1 L/min NO flow from the backup NO module is added to this air/oxygen flow which dilutes the NO concentration down to therapeutic levels. Final NO concentration will depend on the amount of external flow added; for example, a flow of 10 L/min will provide 20 ppm of NO to the patient.
CLOSE

Device Characteristics

MR Unsafe
No
No
Yes
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
37266 Nitric oxide delivery unit, system-based
A mains electricity (AC-powered) device, which may include internal rechargeable batteries, intended for the delivery of precise amounts of nitric oxide (NO), also known as nitrogen monoxide, to the respiratory tract of neonate, paediatric, and adult patients to treat severe respiratory disorders [e.g., primary pulmonary hypertension (PPH), acute respiratory distress syndrome (ARDS)]. It consists of a portable main unit that enables the delivery and monitoring of NO to gases that are to be breathed by the patient via a ventilator or other respiratory device/system. It typically includes accessory items (e.g., tubing, filters) and possibly a trolley (cart) for mobility.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QTB Nitric Oxide Generator And Delivery System
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P200044 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

6d36abcb-c482-4fd6-b3ea-18f687a09897
February 14, 2025
2
August 04, 2022
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
B882900051 5 B882900050 In Commercial Distribution Box
B882900052 12 B882900051 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
1-855-586-4359
xxx@xx.xxx
CLOSE