DEVICE: RED (B960RED201)
Device Identifier (DI) Information
RED
02 2050 RED
In Commercial Distribution
02-2050
Neuraxis, Inc.
02 2050 RED
In Commercial Distribution
02-2050
Neuraxis, Inc.
The Rectal Expulsion Device (RED) is a catheter with a proprietary open-cell foam balloon that naturally expands when inserted into the rectum. RED is used to evaluate the neuromuscular function of the patient's ability to expel its content from the rectum and a qualitative test for rectal hypersensitivity. It is intended to be used in a clinical setting by providers in adult populations. RED has been designed to duplicate test performance of traditional balloon expulsion test (BET) and manual sensation testing devices without needing electronics or software. The insertion end of the device has a rounded tip for comfortable insertion through the anus. Once inserted and opened, the catheter normalizes to atmospheric pressure which allows the foam to passively and safely expand to its original size. The volume the foam displaces when inflated with room air is 52 - 60 ml. This passive expansion provides the same function as filling an empty balloon with water or air, but the proprietary foam behaves and feels like normal stool. When expanded, the volume of material inside the patient’s rectum is perceived by the patient similar to how patients perceive stool, and this may trigger the desire to defecate at lower volumes. This is measured by asking patients a few questions on perceived desire to defecate according to the London Classification that define the evaluation of rectal sensation. After the sensation evaluation, while in the seated or left lateral decubitus position, the patient is instructed to attempt to expel the device in a set amount of time. If the patient is unable to expel the device, the practitioner may gently remove the balloon manually. Cartons may have 1-5 devices as needed.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
17781 | Rectosphincteric balloon |
A hollow rubber structure, expandable with either liquid or air, used in conjunction with a manometer to assess anorectal function (anorectal manometry), typically to evaluate the rectosphincteric reflex upon balloon dilation. The device is typically used in the investigation of lower bowel disorders such as faecal incontinence or Hirschsprung's disease (HD). This is a single-use device.
|
Active | false |
17745 | Gastrointestinal motility manometric catheter, non-electronic |
A non-electrical flexible tube intended to be inserted through the nose or rectum into the gastrointestinal (GI) tract for measuring pressure to assess peristaltic motility in the GI tract (e.g., oesophagus, stomach) or rectal musculature and anal sphincter functions, typically in the evaluation of GI disorders [e.g., gastro-oesophageal reflux disease (GERD), faecal incontinence]. It functions via infusion of water (water-perfused catheter) or insufflation of air/gas (air-charged catheter) into the catheter, whereby pressure signals are conducted to proximally-connected external pressure transducers in/connected to a dedicated analysis system. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KLA | Monitor, Esophageal Motility, Anorectal Motility, And Tube |
FFX | System, Gastrointestinal Motility (Electrical) |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K242304 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
85f91867-e0b3-4f98-9588-05ce265ab970
March 11, 2025
5
January 09, 2025
March 11, 2025
5
January 09, 2025
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
B960RED2011 | 2 | B960RED201 | 2025-01-22 | Not in Commercial Distribution | CARTON |
B960RED2012 | 4 | B960RED201 | 2025-01-22 | Not in Commercial Distribution | box |
B960RED2010 | 1 | B960RED201 | In Commercial Distribution | CARTON | |
B960RED2016 | 6 | B960RED2010 | 2025-01-25 | Not in Commercial Distribution | BOX |
B960RED2015 | 5 | B960RED2010 | 2025-01-25 | Not in Commercial Distribution | BOX |
B960RED2013 | 3 | B960RED2010 | 2025-01-25 | Not in Commercial Distribution | BOX |
B960RED2014 | 4 | B960RED2010 | 2025-01-25 | Not in Commercial Distribution | BOX |
B960RED2017 | 2 | B960RED2010 | 2025-01-25 | Not in Commercial Distribution | BOX |
B960RED2018 | 1 | B960RED2010 | In Commercial Distribution | BOX |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
REDDEVICES5
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
812-689-0791
Tcarrico@neuraxis.com