DEVICE: Cavitron® (D00381840011)

Device Identifier (DI) Information

Cavitron®
8184001
In Commercial Distribution

Dentsply Professional
D00381840011
HIBCC

1
144140845 *Terms of Use
Cavitron® plus Ultrasonic Scaler with Tap-On™ Technology and Cavitron® Steri-Mate® Handpiece with Swivel 115V-Dom
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
36047 Ultrasonic dental scaling/debridement system
An assembly of mains electricity (AC-powered) devices intended to apply ultrasonic oscillations to: 1) mechanically fragment and dislodge gross debris in the dental pulp canal during an endodontic procedure; and/or 2) remove accretions from tooth surfaces during dental cleaning/periodontal therapy. The system typically consists of a generator with controls (e.g., foot-switch) that produces and controls high frequency electric current, and may provide fluid irrigation; a handpiece used to convert the energy to ultrasonic oscillations; and a tip(s) intended to apply the oscillations to the procedure site; tip selection typically affects the intended application (endodontic vs periodontal).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
ELC Scaler, ultrasonic
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity
Special Storage Condition, Specify: Atmospheric limitations 500 to 1060 hPa. Keep Dry. Do not place on or next to a radiator or other heat source.
Storage Environment Temperature: between -40 and 70 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

6fa3b058-d8e4-43ad-ab27-88c200167ba1
March 29, 2018
2
September 23, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
No
No
No CLOSE

Customer Contact

[?]
+1(800)989-8825
xx@xx.xx
CLOSE