Device Identifier (DI) Information

Piccolo Hepatic Function Panel
400-0026
In Commercial Distribution
400-0026
ABAXIS, INC.
EABA40000261
HIBCC

10
555503770 *Terms of Use
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, aspartate aminotransferase, direct bilirubin, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
Yes
No
Yes
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
52929 Total alkaline phosphatase (ALP) IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of total alkaline phosphatase (ALP) in a clinical specimen.
Active false
52925 Alanine aminotransferase (ALT) IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of alanine aminotransferase (ALT) in a clinical specimen.
Active false
53236 Conjugated (direct) bilirubin IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of conjugated (direct) bilirubin in a clinical specimen.
Active false
53599 Albumin IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of albumin in a clinical specimen.
Active false
53989 Total protein IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of total protein in a clinical specimen.
Active false
53231 Total bilirubin IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of total bilirubin in a clinical specimen.
Active false
52955 Total aspartate aminotransferase (AST) IVD, reagent
A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of total aspartate aminotransferase (AST) in a clinical specimen.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
CKF Phenylphosphate, Alkaline Phosphatase Or Isoenzymes
CKA Nadh Oxidation/Nad Reduction, Alt/Sgpt
CJW Bromcresol Purple Dye-Binding, Albumin
CEK Biuret (Colorimetric), Total Protein
CIG Diazo Colorimetry, Bilirubin
CIT Nadh Oxidation/Nad Reduction, Ast/Sgot
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K934592 000
K942782 000
K950164 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 36 and 46 Degrees Fahrenheit
Storage Environment Temperature: between 2 and 8 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

224bae6a-b5d9-404d-a315-5803b8658fff
July 06, 2018
3
September 23, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: EABA40000260 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
Yes
No
No CLOSE

Customer Contact

[?]
1-800-822-2947
Piccolo@abaxis.com
+49 6155780210
abaxis@abaxis.de
+1 (510) 675 6500
abaxis@abaxis.com
CLOSE