The Wi-3 Arm is used to fix the outer (white) HAL-RAR sleeve in place to enhance gradual opening of the RAR window when mucopexy is performed, allowing the surgeon, the nurse or any assistant to comfortably hold the system in position. The Wi-3 HAL-RAR System (HAL - Hemorrhoidal Artery Ligation, RAR - Recto Anal Repair) is a Bluetooth-enabled, pulsed Doppler, ultrasound system intended to be used for detecting hemorrhoidal arteries, to manually ligate these arteries (HAL), and subsequently carry out a mucopexy of hemorrhoidal tissue prolapse (RAR) if necessary.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
44311 Noninvasive vascular ultrasound system
An electrically-powered device assembly consisting of a control unit and an attached probe or interchangeable probes, designed to noninvasively locate and assess the extent of vascular (venous and arterial) flow restriction (e.g., clots, stenosis, mechanical damage) by measuring blood flow rate using ultrasound/Doppler/transit time technology. It may also be used to detect the foetal heartbeat.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
IYN System, Imaging, Pulsed Doppler, Ultrasonic
FHN Ligator, Hemorrhoidal
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal
Storage Environment Humidity: between 10 and 75 Percent (%) Relative Humidity
Storage Environment Temperature: between -20 and 60 Degrees Celsius
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

f3649b49-dd42-450a-ac14-3e948fcb5e71
November 03, 2023
3
January 09, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE