DEVICE: VenteraPointer (EFIAE0129101)
Device Identifier (DI) Information
VenteraPointer
1
Not in Commercial Distribution
Fiagon GmbH
1
Not in Commercial Distribution
Fiagon GmbH
The product VenteraPointer is a variant of a navigated probe for image guided surgical procedures with the
Ventera® Cannulated Articulating Delivery Instrument.
The instrument is intended as an aid for precisely locating anatomical structures in either open or percutaneous
procedures. It is indicated for use with the Fiagon Navigation system using electromagnetic navigation.
The instrument is indicated for any medical condition in which the use of stereotactic surgery may be appropriate,
and where reference to a rigid anatomical structure in the field of ENT surgery can be identified relative to a CT or
MR based model of the anatomy.
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45199 | Multi-purpose stereotactic surgery system |
An electrically-powered assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a surgical procedure of more than one discipline [e.g., orthopaedic and ear/nose/throat (ENT)]. The system may include computerized functions to store diagnostic images used for image-guided surgery.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
PGW | Ear, Nose, And Throat Stereotaxic Instrument |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K141456 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity |
Handling Environment Temperature: between 15 and 35 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c6934da8-6429-4b3c-8bd1-a91b6b02a73d
September 18, 2023
8
August 08, 2016
September 18, 2023
8
August 08, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+13364282241
support@fiagon.com
support@fiagon.com