DEVICE: Epsilon USA (G346EP1830)
Device Identifier (DI) Information
Epsilon USA
EP-183
In Commercial Distribution
EPSILON EYE CARE PRIVATE LIMITED
EP-183
In Commercial Distribution
EPSILON EYE CARE PRIVATE LIMITED
Patil Nucleus Splitter 10° (113 mm overall) Titanium
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| No | |
| No | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 13120 | Ophthalmic surgical probe, reusable |
A slender, rod-like, hand-held manual surgical instrument intended to be used during an ophthalmic procedure to explore, measure, and/or manipulate ocular tissues (e.g., retraction/manipulation of intraocular structures, lens nucleus splitting, removal of foreign bodies in the eye, LASIK flap lifting); it is neither intended to cut tissue nor hook muscles. It is available with a variety of tip shapes including blunt bulbous, hook and T-shape, and the shaft may be straight or bent; it is made of flexible or rigid metallic and/or synthetic polymer material. This is a reusable device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| HND | Spatula, Ophthalmic |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
No
Yes
CLOSE
Yes
| Sterilization Method [?] |
|---|
| Dry Heat Sterilization |
| Moist Heat or Steam Sterilization |
| Ethylene Oxide |
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
be176cb0-7d3d-4622-87f8-3e3b320e13ce
August 03, 2023
2
December 09, 2022
August 03, 2023
2
December 09, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
(909) 984-4614
epsilonusa1@gmail.com
epsilonusa1@gmail.com