BioFlo PICC with Endexo and PASV Valve Technology - 5F x 55cm Dual Lumen Catheter MST-70 Kit
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
36257 | Peripherally-inserted central venous catheter |
A thin, flexible tube intended to be introduced into a peripheral vein and advanced to a central vein for short- to long-term intravascular access to administer medications (antibiotics), chemotherapeutic agents, nutrients, parenteral solutions, pain management fluids, and sometimes for blood sampling, monitoring of blood pressure and temperature, and for power injection of contrast media; it is not primarily intended for extracorporeal blood therapies such as haemodialysis. Also known as a peripherally inserted central catheter (PICC), it typically includes dedicated accessories to facilitate catheter introduction/function (e.g., Luer hubs, stylet). This is a single-use device.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LJS | Catheter,intravascular,therapeutic,long-term greater than 30 days |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Needle Gauge: 21 Gauge |
Catheter Gauge: 5 French |
Length: 55 Centimeter |
Outer Diameter: 1.75 Millimeter |
Device Record Status
eed485f8-c60f-4cd8-b91c-1aaf972b7c7d
January 13, 2023
4
September 15, 2015
January 13, 2023
4
September 15, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
GS1 | 15051684024945 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found