DEVICE: ExoShape (M9701101020000)

Device Identifier (DI) Information

ExoShape
1101-02-000
In Commercial Distribution

Medshape, Inc.
M9701101020000
HIBCC

1
601306413 *Terms of Use
ACL Procedure Pack, Sterile
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35685 Orthopaedic bone wire
A wire intended for the fixation of bone fractures that may be implanted or used short-term (e.g., to hold a plate in the correct position during an intervention). It may be used: 1) as a cerclage wire to aid bone fixation; 2) in a loop or figure-of-eight configuration to reattach, e.g., the tip of the elbow (olecranon), tibial tubercle, or greater trochanter; 3) to augment bone screw/plate fixation; or 4) as a Kirschner wire or K-Wire to stiffen (arthrodese) a toe or finger. It is made of metal [e.g., stainless steel, cobalt-chrome (Co-Cr)], and may be malleable or rigid; some types include a nut designed to be attached to the wire to prevent wire migration. This is a single-use device.
Obsolete false
57874 Suturing unit, single-use
A non-powered, hand-held device intended to pass sutures or a needle/suture assembly through tissues/prosthetic materials to facilitate suturing during an endoscopic and/or open surgical procedure; it may also knot, cut and/or tighten the sutures/ligature loop during or after placement. It typically consists of a shaft with hooks, catches, clasps, or forceps-like jaws at the distal end, and a proximal handle with controls. It typically has a pointed/cutting component to create a suture tunnel, and is loaded with the sutures or the suture is inserted through the shaft. This is a single-use device.
Active false
44877 Ligament graft sizer, noninvasive
A surgical instrument that contains a series of holes of varying dimensions/sizes intended to be used in orthopaedic surgery [e.g., in anterior cruciate ligament (ACL) reconstruction surgery] to measure the size/diameter of a harvested graft to be implanted. It is used ex vivo [e.g., on the preparation table of the operating room (OR)] on a harvested graft. The measurement is subsequently used to determine the diameter of the tunnel drilled into the operative site (e.g., distal femur) for acceptance of the new graft. This is a reusable device.
Active false
61510 Bone tunnel plug, cannulated
A sterile device intended to be inserted into a bone tunnel during an arthroscopic procedure to reduce the loss of the irrigation fluid used to maintain visualization, while allowing the passage of instruments (e.g., probes, guide pins, shavers and graspers) through its lumen to access the joint. It is a short, rigid, cannulated tube which tapers distally with a penetrable seal on the proximal end. It is inserted manually into the bone tunnel, or may be supplied with dedicated instruments for insertion (e.g., obturator). The device is available in a variety of diameters, and is typically made of plastic. This is a single-use device.
Active false
61575 Skin marking pen, single-use
A dedicated pen intended to be used to delineate areas on the skin surface of a patient (e.g., to outline surgical incision sites, for dermatology applications) utilizing non-toxic ink. It is typically a felt-tip pen which may include a sterile disposable ruler. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KDD Kit, Surgical Instrument, Disposable
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

1fe9d257-c97c-484f-949a-d0db056bdd28
February 19, 2024
8
December 15, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
Yes
M97013000102404
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined