Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Iris Scissor Straight Square Edge Shanks Overall Length 3 3/4" (95mm) Sharp Pointed Tips Beveled Blades With Smaller Ring Handles With Precision Two Tone Finish Country Of Origin Germany
Med Saver, Inc.
19-13100
In Commercial Distribution

  • 00194613069544 ()


  • Intraocular scissors, conventional-hinge, reusable
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00757
In Commercial Distribution

  • 00873263007570 ()
KTF1001

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, nonimplantable, single-use
Nadler Style Coaptation Bipolar Forcep With Removable Spacer Stop Overall Length 4 1/4" (107.95mm) With A (High Polished 10mm Long Area) With A Tip Size Of 0.4mm Country of Origin: USA
Med Saver, Inc.
321-140
In Commercial Distribution

  • 00194613074234 ()


  • Open-surgery electrosurgical handpiece/electrode, bipolar, reusable
Shepard Style Bipolar Forcep Angled 4 1/2" (114.3mm) With A (High Polished 10mm Long Area) With A Tip Size Of 0.5mm And 4mm Tying Platforms, Tip Is Angled 45 Degrees Country Of Origin USA
Med Saver, Inc.
19-3161-14A
In Commercial Distribution

  • 00194613071592 ()


  • Open-surgery electrosurgical handpiece/electrode, bipolar, reusable
FRENDâ„¢ Blocking Reagent is provided in 15 tubes, the blocking reagent is buffer based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The Blocking Reagent is provided in a dried solid state.
NanoEnTek, Inc.
FRBR 015
In Commercial Distribution

  • 08809317540825 ()
FRBR 015

  • Immunohistochemistry endogenous protein blocking reagent IVD
IVD reagent kit containing 30 tests.
BIOFIRE DIAGNOSTICS, LLC
RFIT-ASY-0120
Not in Commercial Distribution

  • 00815381020147 ()
RFIT-ASY-0120

  • Multiple-type respiratory pathogen nucleic acid IVD, kit, nucleic acid technique (NAT)
ePlex Respiratory Panel Kit, 12 test, IVD
GENMARK DIAGNOSTICS, INC.
ePlex Respiratory Panel (RP)
In Commercial Distribution

  • 00857167005030 ()
EA001012

  • Multiple-genus respiratory virus antigen IVD, kit, multiplex
ePlex Sample Delivery Device RP Panel
GENMARK DIAGNOSTICS, INC.
ePlex Respiratory Panel (RP)
In Commercial Distribution

  • 00857167005023 ()
KT022006

  • Multiple-genus respiratory virus antigen IVD, kit, multiplex
Respiratory Panel Cartridge
GENMARK DIAGNOSTICS, INC.
ePlex Respiratory Panel (RP)
In Commercial Distribution

  • 00857167005016 ()
KT022287

  • Hepatitis G virus immunoglobulin M (IgM) antibody IVD, kit, enzyme immunoassay (EIA)
No Description
QIAGEN GmbH
V1
In Commercial Distribution

  • 04053228033905 ()
691221

  • Multiple-type respiratory pathogen nucleic acid IVD, kit, nucleic acid technique (NAT)
DR-HO's Perfect Back Rest This product is used for waist massage.Plastic injection molding into the ""S"" type, the external concave can better wrap the back of the human body, the middle part of the hemispherical origin, when the user by pressure, can be very good reaction force to the back, massage the effect.Products by the back, air cushion, fixed belt combination.
Guangzhou Xinbo Electronic Co., Ltd.
PBR-1
In Commercial Distribution

  • 06970742221473 ()


  • Back-filling orthosis
4 Level, 94mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-94
In Commercial Distribution

  • 111106494 ()
  • M364111106FD4940 ()


  • Spinal fixation plate, non-bioabsorbable
4 Level, 90mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-90
In Commercial Distribution

  • 111106490 ()
  • M364111106FD4900 ()


  • Spinal fixation plate, non-bioabsorbable
4 Level, 86mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-86
In Commercial Distribution

  • 111106486 ()
  • M364111106FD4860 ()


  • Spinal fixation plate, non-bioabsorbable
4 Level, 82mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-82
In Commercial Distribution

  • 111106482 ()
  • M364111106FD4820 ()


  • Spinal fixation plate, non-bioabsorbable
4 Level, 78mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-78
In Commercial Distribution

  • 111106478 ()
  • M364111106FD4780 ()


  • Spinal fixation plate, non-bioabsorbable
4 Level, 74mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD4-74
In Commercial Distribution

  • 111106474 ()
  • M364111106FD4740 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 75mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-75
In Commercial Distribution

  • 111106375 ()
  • M364111106FD3750 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 72mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-72
In Commercial Distribution

  • 111106372 ()
  • M364111106FD3720 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 69mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-69
In Commercial Distribution

  • 111106369 ()
  • M364111106FD3690 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 66mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-66
In Commercial Distribution

  • 111106366 ()
  • M364111106FD3660 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 63mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-63
In Commercial Distribution

  • 111106363 ()
  • M364111106FD3630 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 60mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-60
In Commercial Distribution

  • 111106360 ()
  • M364111106FD3600 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 57mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-57
In Commercial Distribution

  • 111106357 ()
  • M364111106FD3570 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 54mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-54
In Commercial Distribution

  • 111106354 ()
  • M364111106FD3540 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 51mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-51
In Commercial Distribution

  • 111106351 ()
  • M364111106FD3510 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 50mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-50
In Commercial Distribution

  • 111106250 ()
  • M364111106FD2500 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 47mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-47
In Commercial Distribution

  • 111106247 ()
  • M364111106FD2470 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 44mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-44
In Commercial Distribution

  • 111106244 ()
  • M364111106FD2440 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 41mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-41
In Commercial Distribution

  • 111106241 ()
  • M364111106FD2410 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 38mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-38
In Commercial Distribution

  • 111106238 ()
  • M364111106FD2380 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 35mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-35
In Commercial Distribution

  • 111106235 ()
  • M364111106FD2350 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 32mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-32
In Commercial Distribution

  • 111106232 ()
  • M364111106FD2320 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 34mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-34
In Commercial Distribution

  • 111106134 ()
  • M364111106FD1340 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 32mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-32
In Commercial Distribution

  • 111106132 ()
  • M364111106FD1320 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 30mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-30
In Commercial Distribution

  • 111106130 ()
  • M364111106FD1300 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 28mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-28
In Commercial Distribution

  • 111106128 ()
  • M364111106FD1280 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 26mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-26
In Commercial Distribution

  • 111106126 ()
  • M364111106FD1260 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 24mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-24
In Commercial Distribution

  • 111106124 ()
  • M364111106FD1240 ()


  • Spinal fixation plate, non-bioabsorbable
1 Level, 22mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-22
In Commercial Distribution

  • 111106122 ()
  • M364111106FD1220 ()


  • Spinal fixation plate, non-bioabsorbable
< 1 ... 87 88 89 90 91 ... 112 >