Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

EARP, IMPLANT CADDIE 14X30. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1430
In Commercial Distribution

  • 00810135960946 ()


  • Surgical instrument/implant rack
EARP, IMPLANT CADDIE 14X25. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-IC_1425
In Commercial Distribution

  • 00810135960939 ()


  • Surgical instrument/implant rack
EARP, DISC SPACER CADDIE. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DC
In Commercial Distribution

  • 00810135960922 ()


  • Surgical instrument/implant rack
EARP, TRIAL 22X35X14 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-1214
In Commercial Distribution

  • 00810135960908 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X12 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-1212
In Commercial Distribution

  • 00810135960892 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X14 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0614
In Commercial Distribution

  • 00810135960885 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X12 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0612
In Commercial Distribution

  • 00810135960878 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 22X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0610
In Commercial Distribution

  • 00810135960861 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1214
In Commercial Distribution

  • 00810135960854 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1212
In Commercial Distribution

  • 00810135960847 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0614
In Commercial Distribution

  • 00810135960830 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0612
In Commercial Distribution

  • 00810135960823 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0610
In Commercial Distribution

  • 00810135960816 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0008
In Commercial Distribution

  • 00810135960809 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 8 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X10 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0010
In Commercial Distribution

  • 00810135960793 ()

  • Depth: 14 Millimeter
  • Width: 35 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0008
In Commercial Distribution

  • 00810135960786 ()

  • Height: 8 Millimeter
  • Depth: 14 Millimeter
  • Width: 35 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X25X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1425-0008
In Commercial Distribution

  • 00810135960779 ()

  • Height: 8 Millimeter
  • Width: 25 Millimeter
  • Depth: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-002
In Commercial Distribution

  • 00810135960618 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 14MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-14
In Commercial Distribution

  • 00810135960601 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 12MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-12
In Commercial Distribution

  • 00810135960595 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 10MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-10
In Commercial Distribution

  • 00810135960588 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 8MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-08
In Commercial Distribution

  • 00810135960571 ()


  • General internal orthopaedic fixation system implantation kit
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3071
In Commercial Distribution

  • 08806395496303 ()
3300-3071

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3070
In Commercial Distribution

  • 08806395496297 ()
3300-3070

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3069
In Commercial Distribution

  • 08806395496280 ()
3300-3069

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3068
In Commercial Distribution

  • 08806395496273 ()
3300-3068

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3067
In Commercial Distribution

  • 08806395496266 ()
3300-3067

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3066
In Commercial Distribution

  • 08806395496259 ()
3300-3066

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3065
In Commercial Distribution

  • 08806395496242 ()
3300-3065

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3064
In Commercial Distribution

  • 08806395496235 ()
3300-3064

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3063
In Commercial Distribution

  • 08806395496228 ()
3300-3063

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3062
In Commercial Distribution

  • 08806395496211 ()
3300-3062

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3061
In Commercial Distribution

  • 08806395496204 ()
3300-3061

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3060
In Commercial Distribution

  • 08806395496198 ()
3300-3060

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3059
In Commercial Distribution

  • 08806395496181 ()
3300-3059

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3058
In Commercial Distribution

  • 08806395496174 ()
3300-3058

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3057
In Commercial Distribution

  • 08806395496167 ()
3300-3057

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3056
In Commercial Distribution

  • 08806395496150 ()
3300-3056

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3055
In Commercial Distribution

  • 08806395496143 ()
3300-3055

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3054
In Commercial Distribution

  • 08806395496136 ()
3300-3054

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3053
In Commercial Distribution

  • 08806395496129 ()
3300-3053

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3052
In Commercial Distribution

  • 08806395496112 ()
3300-3052

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3051
In Commercial Distribution

  • 08806395496105 ()
3300-3051

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3050
In Commercial Distribution

  • 08806395496099 ()
3300-3050

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3049
In Commercial Distribution

  • 08806395496082 ()
3300-3049

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3048
In Commercial Distribution

  • 08806395496075 ()
3300-3048

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3047
In Commercial Distribution

  • 08806395496068 ()
3300-3047

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-2054
In Commercial Distribution

  • 08806395496051 ()
3300-2054

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-2053
In Commercial Distribution

  • 08806395496044 ()
3300-2053

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-2052
In Commercial Distribution

  • 08806395496037 ()
3300-2052

  • Spinal fixation plate, non-bioabsorbable
< 1 ... 78 79 80 81 82 ... 88 >