Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00757
In Commercial Distribution

  • 00873263007570 ()
KTF1001

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, nonimplantable, single-use
primaLOK SP 18mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0118-00
In Commercial Distribution

  • 00813210021778 ()

  • Height: 18 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 12mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0112-00
In Commercial Distribution

  • 00813210021754 ()

  • Height: 12 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 15mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0115-00
In Commercial Distribution

  • 00813210021761 ()

  • Height: 15 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 10mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0110-00
In Commercial Distribution

  • 00813210021747 ()

  • Height: 10 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 8mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0108-00
In Commercial Distribution

  • 00813210021730 ()

  • Height: 8 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 6mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0106-00
In Commercial Distribution

  • 00813210021723 ()

  • Height: 6 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 28mm Medium Boxless Implant, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0828-00
In Commercial Distribution

  • 00813210021785 ()

  • Width: 28 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD9
In Commercial Distribution

  • 1199029 ()
  • M364119902FD90 ()

  • Outer Diameter: 18 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD8
In Commercial Distribution

  • 1199028 ()
  • M364119902FD80 ()

  • Outer Diameter: 16 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage