microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Platform
FHC, INC.
44975L-00263
In Commercial Distribution
- 10873263002633 ()
- 00873263002636 ()
- Impedance: Megaohms
- Length: 220.72 Millimeter
- Outer Diameter: 0.55 Millimeter
- Length: 10 Millimeter
- Length: 205.72 Millimeter
44975L
- Depth electrode
microTargeting(TM) Electrode, 1x, sterile, R.ZAP, Platform
FHC, INC.
44970R-00259
In Commercial Distribution
- 10873263002596 ()
- 00873263002599 ()
- Length: 205.72 Millimeter
- Impedance: Megaohms
- Outer Diameter: 0.55 Millimeter
- Length: 220.72 Millimeter
- Length: 10 Millimeter
44970R
- Depth electrode
microTargeting LP+ Patient Lead, Sterile, for use with microTargting Electrodes
FHC, INC.
66-EL-LP-00258
In Commercial Distribution
- 00873263002582 ()
66-EL-LP
- Depth electrode
microTargeting Electrode Cable w/ Alligator Clips, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-01-00257
In Commercial Distribution
- 00873263002575 ()
66-EL-EC-01
- Depth electrode
microTargeting(TM) Electrode, 1x, sterile, single, D.ZAP(Z), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685Z-00254
In Commercial Distribution
- 10873263002541 ()
- 00873263002544 ()
- Length: 256.4 Millimeter
- Impedance: Megaohms
- Length: 271.4 Millimeter
- Length: 10 Millimeter
- Outer Diameter: 0.77 Millimeter
34685Z
- Depth electrode
microTargeting(TM) Electrode, sterile, single, D.ZAP(L), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685L-00252
In Commercial Distribution
- 10873263002527 ()
- 00873263002520 ()
- Length: 256.4 Millimeter
- Length: 10 Millimeter
- Outer Diameter: 0.77 Millimeter
- Impedance: Megaohms
- Length: 271.4 Millimeter
34685L
- Depth electrode
microTargeting(TM) Electrode, differential, sterile, single, 1 Meg for use with Frame and STar or MT Drive
FHC, INC.
34680R-00250
In Commercial Distribution
- 10873263002503 ()
- 00873263002506 ()
- Impedance: Megaohms
- Length: 10 Millimeter
- Outer Diameter: 0.77 Millimeter
- Length: 256.4 Millimeter
- Length: 271.4 Millimeter
34680R
- Depth electrode
microTargeting(TM) Electrode, sterile, 1x, array, D.ZAP(Z) for use with Frame and STar or MT Drive
FHC, INC.
22675Z-00246
In Commercial Distribution
- 10873263002466 ()
- 00873263002469 ()
- Length: 276.5 Millimeter
- Length: 10 Millimeter
- Length: 261.5 Millimeter
- Outer Diameter: 0.55 Millimeter
- Impedance: Megaohms
22675Z
- Depth electrode
microTargeting Array Electrode, 1x, sterile, D.ZAP(L) for use with Frame, STar or MT Drive
FHC, INC.
22675L-00244
In Commercial Distribution
- 10873263002442 ()
- 00873263002445 ()
- Impedance: Megaohms
- Length: 261.5 Millimeter
- Length: 276.5 Millimeter
- Length: 10 Millimeter
- Outer Diameter: 0.55 Millimeter
22675L
- Depth electrode
microTargeting Array Electrode, sterile, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
22670R-00242
In Commercial Distribution
- 10873263002428 ()
- 00873263002421 ()
- Impedance: Megaohms
- Length: 261.5 Millimeter
- Outer Diameter: 0.55 Millimeter
- Length: 276.5 Millimeter
- Length: 10 Millimeter
22670R
- Depth electrode
microTargeting Electrode Cable, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-00155
In Commercial Distribution
- 00873263001554 ()
66-EL-EC
- Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00151
In Commercial Distribution
- 00873263001516 ()
FC1020
- Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00139
In Commercial Distribution
- 00873263001394 ()
FC1020
- Depth electrode
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable.
Contains:
IT(BP2): Insertion Tube.
2x MTDWLN(BP)(BP7): microTargeting Electrode.
PT(BP2): Protective Tube.
Sterile Drape Sleeve for microTargeting motor
FC1020 Electrode Lead
Individual Specifications:
IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar).
MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L)
PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID
OD: 0.77mm
FHC, INC.
KTF1001-00133
Not in Commercial Distribution
- 00873263001332 ()
KTF1001
- Patient surgical drape, single-use
- Intracerebral cannula, implantable
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(AR)(AR7)-00865
In Commercial Distribution
- 00873263008652 ()
- 10873263008659 ()
MTDWZP(AR)(AR7)
- Depth electrode
microTargeting™ Platform Electrodes 5x Sterile
FHC, INC.
44375Z-00798
In Commercial Distribution
- 10873263007980 ()
- 00873263007983 ()
- Length: 3 Millimeter
- Impedance: Megaohms
- Outer Diameter: 0.55 Millimeter
- Length: 212.72 Millimeter
- Length: 220.72 Millimeter
44375Z
- Depth electrode
microTargeting™ Single Frame Platinum 5X Sterile
FHC, INC.
35385Z-00796
In Commercial Distribution
- 10873263007966 ()
- 00873263007969 ()
- Length: 3 Millimeter
- Length: 263.4 Millimeter
- Outer Diameter: 0.86 Millimeter
- Impedance: Megaohms
- Length: 271.4 Millimeter
35385Z
- Depth electrode
microTargeting™ Array Electrodes 5x Sterile
FHC, INC.
22375Z-00790
In Commercial Distribution
- 10873263007904 ()
- 00873263007907 ()
- Length: 268.5 Millimeter
- Impedance: Megaohms
- Outer Diameter: 0.55 Millimeter
- Length: 3 Millimeter
- Length: 276.5 Millimeter
22375Z
- Depth electrode
GL5 UE Patient Lead, 1.5m, presterile
FHC, INC.
C0231-00691
In Commercial Distribution
- 00873263006917 ()
- Length: 1.5 Meter
C0231
- Depth electrode
microTargeting(TM) Electrode, Back loaded, Platinum/Iridium with Glass Insulation, Presterile
FHC, INC.
MTBPBP(DT1)-00672
In Commercial Distribution
- 10873263006723 ()
- 00873263006726 ()
- Length: 300 Millimeter
- Length: 10 Millimeter
- Outer Diameter: 0.63 Millimeter
- Impedance: Megaohms
MTBPBP(DT1)
- Depth electrode
microTargeting™ Electrodes, differential, tungsten, sterile, DZAP
FHC, INC.
MTDWZP(SS)(BP8)-00661
In Commercial Distribution
- 10873263006617 ()
- 00873263006610 ()
- Length: 263.4 Millimeter
- Outer Diameter: 0.7 Millimeter
- Length: 268.4 Millimeter
- Impedance: Megaohms
- Length: 3 Millimeter
MTDWZP(SS)(BP8)
- Depth electrode
microTargeting™ Electrodes, differential, tungsten, sterile, LZAP
FHC, INC.
MTDWLP(SS)(BP8)-00659
In Commercial Distribution
- 10873263006594 ()
- 00873263006597 ()
- Outer Diameter: 0.7 Millimeter
- Length: 263.4 Millimeter
- Length: 3 Millimeter
- Length: 268.4 Millimeter
- Impedance: Megaohms
MTDWLP(SS)(BP8)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(AO)(AO1)-00542
In Commercial Distribution
- 10873263005429 ()
- 00873263005422 ()
- Length: 3 Millimeter
- Impedance: Megaohms
- Outer Diameter: 1.27 Millimeter
- Length: 274 Millimeter
- Length: 282 Millimeter
MTDWBP(AO)(AO1)
- Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, DZAP(L), sterile
FHC, INC.
MTSWLP(JN)(JN1)-00492
In Commercial Distribution
- 10873263004927 ()
- 00873263004920 ()
- Impedance: Megaohms
- Length: 251.4 Millimeter
- Length: 278.4 Millimeter
- Length: 25 Millimeter
- Outer Diameter: 0.77 Millimeter
MTSWLP(JN)(JN1)
- Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, sterile
FHC, INC.
MTSWBP(JN)(JN2)-00490
In Commercial Distribution
- 10873263004903 ()
- 00873263004906 ()
- Impedance: Megaohms
- Outer Diameter: 0.77 Millimeter
- Length: 16 Millimeter
- Length: 288.4 Millimeter
- Length: 270.4 Millimeter
MTSWBP(JN)(JN2)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(SP)(AR5)-00472
In Commercial Distribution
- 10873263004729 ()
- 00873263004722 ()
- Length: 266.5 Millimeter
- Length: 5 Millimeter
- Impedance: Megaohms
- Outer Diameter: 0.55 Millimeter
- Length: 276.5 Millimeter
MTDWZP(SP)(AR5)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SL2)-00464
In Commercial Distribution
- 10873263004644 ()
- 00873263004647 ()
- Length: 10 Millimeter
- Length: 274.65 Millimeter
- Outer Diameter: 0.55 Millimeter
- Impedance: Megaohms
- Length: 258 Millimeter
MTDWZP(NS)(SL2)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SK2)-00462
In Commercial Distribution
- 10873263004620 ()
- 00873263004623 ()
- Length: 10 Millimeter
- Impedance: Megaohms
- Outer Diameter: 0.55 Millimeter
- Length: 243.65 Millimeter
- Length: 227 Millimeter
MTDWZP(NS)(SK2)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(SB)(SB2)-00390
In Commercial Distribution
- 10873263003906 ()
- 00873263003909 ()
- Length: 260 Millimeter
- Impedance: Megaohms
- Length: 6 Millimeter
- Outer Diameter: 0.55 Millimeter
- Length: 272.65 Millimeter
MTDWBP(SB)(SB2)
- Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(LS)(LS3)-00388
In Commercial Distribution
- 10873263003883 ()
- 00873263003886 ()
- Impedance: Megaohms
- Length: 10 Millimeter
- Outer Diameter: 0.77 Millimeter
- Length: 291.5 Millimeter
- Length: 273.5 Millimeter
MTDWBP(LS)(LS3)
- Depth electrode