Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SEEG DEPTH ELECTRODE, 18 CONTACTS, EXPLORATION LENGTH 50MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539004372 ()

  • "8 contacts with Contact Length 1 Millimeters and Contact Spacing 2 Millimeters 10 Contacts with Contact Length 2 Millimeters and Contact Spacing 3,5 Millimeters"
D08-18PIX

  • Depth electrode
SEEG DEPTH ELECTRODE, 15 CONTACTS, EXPLORATION LENGTH 29MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539004365 ()

  • Contact Length 1 Millimeters Contact Spacing 2 Millimeters
D08-15PIX

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004341 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°11 and n°12"
MM08-12L41P08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004334 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°10 and n°11"
MM08-12L41M08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004327 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°9 and n°10"
MM08-12L41L08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004310 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°8 and n°9"
MM08-12L41K08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004303 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°7 and n°8"
MM08-12L41J08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004297 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°6 and n°7"
MM08-12L41I08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004280 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°5 and n°6"
MM08-12L41H08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004273 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°4 and n°5"
MM08-12L41G08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004266 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°3 and n°4"
MM08-12L41F08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004259 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°2 and n°3"
MM08-12L41E08

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004242 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°1 and n°2"
MM08-12L41D08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004235 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°7 and n°8"
MM08-08L27P08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004228 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°6 and n°7"
MM08-08L27I08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004211 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°5 and n°6 "
MM08-08L27H08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004204 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°4 and n°5"
MM08-08L27G08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004198 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°3 and n°4"
MM08-08L27F08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004181 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°2 and n°3"
MM08-08L27E08

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 MACRO AND 8 MICRO-CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM
DIXI MEDICAL
MICRO MACRO ELECTRODE
In Commercial Distribution

  • 03664539004174 ()

  • "Macro Contact Length 2 Millimeters Macro Contact Spacing 1.5 Millimeters Micro Contact Exposure Diameter 0,02 Millimeters Microcontacts exit position: between contacts n°1 and n°2"
MM08-08L27D08

  • Depth electrode
< 1 2 3 4 5 6 >

Having trouble finding the UDI and/or device in GUDID? Send a picture of the label to GUDIDSupport@fda.hhs.gov.