Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0608SN
In Commercial Distribution

  • 00085412530673 ()
PC0608SNBIO

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0404SN
In Commercial Distribution

  • 00085412530642 ()
PC0404SNBIO

  • Cardiovascular patch, animal-derived
With EnCap Technology
ST. JUDE MEDICAL, INC.
C0914
In Commercial Distribution

  • 05414734007276 ()

  • Length: 14 Centimeter
  • Width: 9 Centimeter
C0914

  • Cardiovascular patch, animal-derived
With EnCap Technology
ST. JUDE MEDICAL, INC.
C0510
In Commercial Distribution

  • 05414734007269 ()

  • Length: 10 Centimeter
  • Width: 5 Centimeter
C0510

  • Cardiovascular patch, animal-derived
With EnCap Technology
ST. JUDE MEDICAL, INC.
C0205
In Commercial Distribution

  • 05414734007252 ()

  • Width: 2 Centimeter
  • Length: 5 Centimeter
C0205

  • Cardiovascular patch, animal-derived
Pericardial Patch
ST. JUDE MEDICAL, INC.
C0405
In Commercial Distribution

  • 05414734054881 ()

  • Length: 5 Centimeter
  • Width: 4 Centimeter
C0405

  • Cardiovascular patch, animal-derived
4.25mm dia.12mm long variable screw Implant. The Quantum Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PCP-425-12V
In Commercial Distribution

  • 90810005669170 ()

  • Outer Diameter: 4.25 Millimeter
  • Length: 12 Millimeter


  • Intervertebral-body internal spinal fixation system
3.75mm dia.14mm long variable screw Implant. The Quantum Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PCP-375-14V
In Commercial Distribution

  • 90810005669125 ()

  • Outer Diameter: 3.75 Millimeter
  • Length: 14 Millimeter


  • Intervertebral-body internal spinal fixation system
4.25mm dia.14mm long fixed screw Implant. The Quantum Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PCP-425-14F
In Commercial Distribution

  • 90810005669064 ()

  • Outer Diameter: 4.25 Millimeter
  • Length: 14 Millimeter


  • Intervertebral-body internal spinal fixation system
4.25mm dia.12mm long fixed screw Implant. The Quantum Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PCP-425-12F
In Commercial Distribution

  • 90810005669057 ()

  • Outer Diameter: 4.25 Millimeter
  • Length: 12 Millimeter


  • Intervertebral-body internal spinal fixation system
ProxiCor for Pericardial Closure is a decellularized natural scaffold for repairing the pericardium following cardiac surgery.
AZIYO BIOLOGICS, INC.
CMCV-060-402
In Commercial Distribution

  • 10859389005017 ()
  • 00859389005010 ()

  • Width: 7.0 Centimeter
  • Height: 15.0 Centimeter


  • Cardiovascular patch, animal-derived
ProxiCor for Pericardial Closure is a decellularized natural scaffold for repairing the pericardium following cardiac surgery.
AZIYO BIOLOGICS, INC.
CMCV-059-401
In Commercial Distribution

  • 00859389005003 ()
  • 10859389005000 ()

  • Height: 10 Centimeter
  • Width: 7 Centimeter


  • Cardiovascular patch, animal-derived
ProxiCor for Cardiac Tissue Repair is indicated for use as an intracardiac patch or pledget for tissue repair and suture-line buttressing.
AZIYO BIOLOGICS, INC.
CMCV-067-404
In Commercial Distribution

  • 10859389005055 ()
  • 00859389005058 ()

  • Width: 7 Centimeter
  • Height: 4 Centimeter


  • Cardiovascular patch, animal-derived
ProxiCor for Cardiac Tissue Repair is indicated for use as an intracardiac patch or pledget for tissue repair and suture-line buttressing.
AZIYO BIOLOGICS, INC.
CMCV-064-401
In Commercial Distribution

  • 10859389005048 ()
  • 00859389005041 ()

  • Width: 7 Centimeter
  • Height: 10 Centimeter


  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP2X9
In Commercial Distribution

  • 00877234000652 ()

  • Width: 2 Centimeter
  • Length: 9 Centimeter
PFP2X9

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP1X14
In Commercial Distribution

  • 00877234000645 ()

  • Width: 1 Centimeter
  • Length: 14 Centimeter
PFP1X14

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP1X10
In Commercial Distribution

  • 00877234000638 ()

  • Width: 1 Centimeter
  • Length: 10 Centimeter
PFP1X10

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP4X4
In Commercial Distribution

  • 00877234000546 ()

  • Width: 4 Centimeter
  • Length: 4 Centimeter
PFP4X4

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP6X8
In Commercial Distribution


  • Width: 6 Centimeter
  • Length: 8 Centimeter
PFP6X8

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP8X14
In Commercial Distribution

  • 00877234000560 ()

  • Width: 8 Centimeter
  • Length: 14 Centimeter
PFP8X14

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP0.8X8
In Commercial Distribution

  • 00877234000553 ()

  • Width: 0.8 Centimeter
  • Length: 8 Centimeter
PFP0.8X8

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP1X6
In Commercial Distribution

  • 00877234000539 ()

  • Width: 1 Centimeter
  • Length: 6 Centimeter
PFP1X6

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
Artivion, Inc.
PFP 6x8
In Commercial Distribution


  • Width: 6 Centimeter
  • Length: 8 Centimeter
PFP 6x8

  • Cardiovascular patch, animal-derived
Decellularized Bovine Pericardium
GENESEE BIOMEDICAL, INC.
PFP6x8
In Commercial Distribution

  • B040PFP6X81 ()
N/A

  • Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG0608
In Commercial Distribution

  • 00085412818443 ()
PG0608

  • Cardiovascular patch, animal-derived
Peri-Guard Repair Patch (Peri-Guard) is a biologic tissue prepared from bovine pericardium cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. Peri-Guard is chemically sterilized using ethanol and propylene oxide. Peri-Guard is treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25C.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0404N
In Commercial Distribution

  • 00085412530529 ()
PC0404NBIO

  • Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG1225
In Commercial Distribution

  • 00085412818658 ()
PG1225

  • Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG1016
In Commercial Distribution

  • 00085412818610 ()
PG1016

  • Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG0814
In Commercial Distribution

  • 00085412818597 ()
PG0814

  • Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG0404
In Commercial Distribution

  • 00085412818405 ()
PG0404

  • Cardiovascular patch, animal-derived
< 1 ... 2 3 4 5 6 ... 43 >