SEARCH RESULTS FOR: Origin(1746 results)
Recharger for inFlow Activator
VESIFLO INC
August 2021
In Commercial Distribution
- 00862563003177 ()
403320
- Intraurethral valve/pump
Unit for storing and recharging the inFlow Activator
VESIFLO INC
August 2021
In Commercial Distribution
- 00862563003160 ()
403310
- Intraurethral valve/pump
Magnetic remote control for the inFlow Device
VESIFLO INC
August 2021
In Commercial Distribution
- 00862563003153 ()
403300
- Intraurethral valve/pump
The Atalante X by Wandercraft is a completely self-balancing walking system for people with mobility disabilities. It is a fully powered hip-knee-ankle lower body exoskeleton with 12 actuated degrees of freedom. Atalante X is self-balancing and includes dynamic-walking control. Dynamic walking allows the Atalante X to consume significantly less power and have a more natural gait. The Atalante X is a tool for physical therapy.
It is meant to be highly adjustable and be applicable for various stages of physical rehabilitation, re-mobilization and exercises.
WANDERCRAFT
ATA-002-EN US
In Commercial Distribution
- 03665965000129 ()
- Programmable ambulation exoskeleton, clinical
primaLOK SP 28mm Medium Boxless Implant, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0828-00
In Commercial Distribution
- 00813210021785 ()
- Width: 28 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 18mm Implant Assembly, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0118-00
In Commercial Distribution
- 00813210021778 ()
- Height: 18 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 15mm Implant Assembly, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0115-00
In Commercial Distribution
- 00813210021761 ()
- Height: 15 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 12mm Implant Assembly, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0112-00
In Commercial Distribution
- 00813210021754 ()
- Height: 12 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 10mm Implant Assembly, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0110-00
In Commercial Distribution
- 00813210021747 ()
- Height: 10 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 8mm Implant Assembly, Sterile
The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0108-00
In Commercial Distribution
- 00813210021730 ()
- Height: 8 Millimeter
- Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial