SEARCH RESULTS FOR: AT(272777 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Elvarex 2/Thigh High/Profile-Slant-Open Toe/Thigh high slip form without volant to sew at body bandage
BSN-Jobst GmbH
77556-00298-00
In Commercial Distribution
- 04019702248234 ()
- Pressure: 23-32 mmHg
- Compression/pressure sock/stocking, reusable
Elvarex 2/Thigh High/Open Toe/Thigh high slip form without volant to sew at body bandage
BSN-Jobst GmbH
77556-00223-00
In Commercial Distribution
- 04019702181135 ()
- Pressure: 23-32 mmHg
- Compression/pressure sock/stocking, reusable
Elvarex 3/Mid Thigh High/Slant-Closed Toe-Elephantiasis-Version/Thigh high without volant to sew at body bandage/Black
BSN-Jobst GmbH
77372-00653-00
In Commercial Distribution
- 04019702533637 ()
- Pressure: 34-46 mmHg
- Compression/pressure sock/stocking, reusable
Elvarex 4 Super/Thigh High/Open Toe/Thigh high without volant to sew at body bandage/Black
BSN-Jobst GmbH
77453-00231-00
In Commercial Distribution
- 04019702507638 ()
- Pressure: >49 mmHg
- Compression/pressure sock/stocking, reusable
Secto® Handle, Laparoscopic, (SGH10 at 20 cm WL), Short, 10 mm, 20.5 cm Working Length, Reusable
SYMMETRY SURGICAL INC.
SGH1032
Not in Commercial Distribution
- 00887482155745 ()
- Laparoscopic surgery handle
Gravity Compensating Accessory, Low Pressure Range (White)
NATUS MEDICAL INCORPORATED
NT903430
In Commercial Distribution
- 00382830056076 ()
- 10381780033516 ()
- Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 140-170mmH2O
NT903430
- Ventriculo-peritoneal/atrial shunt
Gravity Compensating Accessory, Medium Pressure Range (Yellow)
NATUS MEDICAL INCORPORATED
NT903435
In Commercial Distribution
- 00382830055437 ()
- 10381780033523 ()
- Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 200-250mmH2O
NT903435
- Ventriculo-peritoneal/atrial shunt
RENASYS EDGE Carry Straps
SMITH & NEPHEW MEDICAL LIMITED
66803137
In Commercial Distribution
- 05000223501150 ()
- 05000223501143 ()
- 42x135x12 milimeter W x H x D (approximate dimensions with strap at longest)
66803137
- Negative-pressure wound therapy system, electric, reusable
The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
903435
Not in Commercial Distribution
- 10381780033523 ()
- M2729034351 ()
- Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 200-250mmH2O
903435
- Ventriculo-peritoneal/atrial shunt
The Gravity Compensating Accessory (GCA) is designed to counterbalance gravity’s effects on the fluid column within the drainage catheter of an implanted shunt system. The GCA consists of a silicone elastomer encased stainless steel housing with a ruby ball held in a stainless steel seat (in the vertical orientation) by two to four stainless steel balls. In the horizontal orientation, a minimal resistance to flow (<30mmH2O at 5ml/h) is added to the system, and in the vertical orientation: 140-170, 200-250 or 260-320mmH2O (at 5ml/h).
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
903430
Not in Commercial Distribution
- 10381780033516 ()
- M2729034301 ()
- Additional Resistance to Flow at 5ml/h, Horizontal Orientation < 30mmH2O, Vertical Orientation: 140-170mmH2O
903430
- Ventriculo-peritoneal/atrial shunt