SEARCH RESULTS FOR: (*bitcoin mining hardware comparison馃挷itenthusiasts.com馃挷Cryptocurrency*)(5684 results)
Jaw Tracker T (JTT31)
Claronav Inc
955-ND-JTTA-000
In Commercial Distribution
- 07540209955808 ()
955-ND-JTTA-000
- Surgical planning/navigation-enhancement system
Jaw Tracker U
Claronav Inc
955-ND-JTVU
In Commercial Distribution
- 07540209955792 ()
955-ND-JTVU
- Surgical planning/navigation-enhancement system
Jaw Tracker C
Claronav Inc
955-ND-JTVC
In Commercial Distribution
- 07540209955785 ()
955-ND-JTVC
- Surgical planning/navigation-enhancement system
Jaw Tracker B
Claronav Inc
955-ND-JTVB
In Commercial Distribution
- 07540209955778 ()
955-ND-JTVB
- Surgical planning/navigation-enhancement system
Tracer 3
Claronav Inc
955-ND-TRTO (Version 3)
In Commercial Distribution
- 07540209955761 ()
955-ND-TRTO
- Surgical planning/navigation-enhancement system
Navident Training Kit for use with the Navident system
Claronav Inc
955-ND-NVTK
In Commercial Distribution
- 07540209955044 ()
- Surgical planning/navigation-enhancement system
Navident accessory kit for use with Navident System
Claronav Inc
955-ND-ACCK
In Commercial Distribution
- 07540209955037 ()
- Surgical planning/navigation-enhancement system
Navident Surgical Navigation System - Packaged System (including kits/accessories)
Claronav Inc
955-ND-ND, plus kits
In Commercial Distribution
- 07540209955006 ()
- Surgical planning/navigation-enhancement system
SyMRI is a post-processing software medical device intended for use in visualization of soft tissue. SyMRI analyzes input data from MR imaging systems. SyMRI utilizes data from supported MR sequences to generate parametric maps of R1, R2 relaxation rates, and proton density (PD).
SyMRI is intended for automatic labeling, visualization and volumetric quantification of segmentable brain tissues from a set of MR images. Brain tissue volumes are determined based on modeling of parametric maps from SyMRI.
SyMRI can also generate multiple image contrasts from the parametric maps. SyMRI enables post-acquisition image contrast adjustment.
SyMRI is indicated for head imaging.
When interpreted by a trained physician, output from SyMRI can provide information useful in determining diagnosis. SyMRI 2D is intended to be used in combination with at least one other, conventional MR acquisition (e.g. T2-FLAIR). T1W and T2W images from SyMRI 3D may replace conventional MR images in a clinical setting when interpreting together with a conventional 3D T2W FLAIR image.
SyntheticMR AB (publ)
15
In Commercial Distribution
- 07340024700078 ()
- MRI system application software
SyMRI is a post-processing software medical device intended for use in visualization of the brain. SyMRI analyzes input data from MR imaging systems. SyMRI utilizes data from a multi-delay, multi-echo acquisition (MDME) to generate parametric maps of R1, R2 relaxation rates, and proton density (PD). SyMRI can generate multiple image contrasts from the parametric maps. SyMRI enables post-acquisition image contrast adjustment. SyMRI is indicated for head imaging.
SyMRI is also intended for automatic labeling, visualization and volumetric quantification of segmentable brain tissues from a set of MR images. Brain tissue volumes are determined based on modeling of parametric maps from MDME images.
When interpreted by a trained physician, SyMRI images can provide information useful in determining diagnosis. SyMRI should always be used in combination with at least one other, conventional MR acquisition (e.g. T2-FLAIR).
SyntheticMR AB (publ)
11
In Commercial Distribution
- 07340024700030 ()
- MRI system application software