The iSnare system is a dual lumen device providing both needle injection and monopolar electrocautery polypectomy snare capability within a single catheter device.
US Endoscopy
00711085
In Commercial Distribution

  • 10724995180796 ()
  • 00724995180799 ()
  • 00816765010914 ()

  • Needle Gauge: 23 Gauge
  • Width: 2.5 Millimeter
  • Length: 230 Centimeter
00711085

  • Endoscopic electrosurgical submucosal lift/resection set
The iSnare system-Lariat snare is used to inject various types of media and to grasp, dissect and transect tissue during gastrointestinal endoscopy procedures, and can be used with or without monopolar diathermic energy.
US Endoscopy
00711084
In Commercial Distribution

  • 10724995180789 ()
  • 00724995180782 ()
  • 00816765012741 ()

  • Outer Diameter: 2.5 Millimeter
  • Width: 30 Millimeter
  • Needle Gauge: 25 Gauge
  • Length: 230 Centimeter
00711084

  • Endoscopic electrosurgical submucosal lift/resection set
Ultramatrix EUS balloon-Olympus Pentax radial is used for endoscopic ultrasound applications using the balloon method in the gastrointestinal tract.
US Endoscopy
USBOR
In Commercial Distribution

  • 10724995180772 ()
  • 00724995180775 ()
  • 00816765014332 ()
USBOR

  • Ultrasound endoscope balloon, synthetic polymer
The Ultramatrix EUS balloon -Olympus linear is used for endoscopic ultrasound applications using the balloon method in the gastrointestinal tract.
US Endoscopy
USBOL
In Commercial Distribution

  • 10724995180765 ()
  • 00724995180768 ()
  • 00816765014325 ()
USBOL

  • Ultrasound endoscope balloon, synthetic polymer
The Bipolar Hemostatic Probe is passed through an endoscope's working channel to provide hemostasis throughout the gastrointestinal tract.
US Endoscopy
00711847
Not in Commercial Distribution

  • 10724995180703 ()
  • 00724995180706 ()
  • 00816765012086 ()

  • Length: 350 Centimeter
  • Outer Diameter: 3.3 Millimeter
00711847

  • Endoscopic electrosurgical electrode, bipolar, single-use
The Bipolar Hemostatic Probe is passed through an endoscope's working channel to provide hemostasis throughout the gastrointestinal tract.
US Endoscopy
00711843
Not in Commercial Distribution

  • 10724995180697 ()
  • 00724995180690 ()
  • 00816765012079 ()

  • Length: 350 Centimeter
  • Outer Diameter: 2.3 Millimeter
00711843

  • Endoscopic electrosurgical electrode, bipolar, single-use
The Bipolar Hemostatic Probe is passed through an endoscope's working channel to provide hemostasis throughout the gastrointestinal tract.
US Endoscopy
00711841
Not in Commercial Distribution

  • 10724995180680 ()
  • 00724995180683 ()
  • 00816765012062 ()

  • Length: 350 Centimeter
  • Outer Diameter: 2.3 Millimeter
00711841

  • Endoscopic electrosurgical electrode, bipolar, single-use
The BioGuard valves (4-piece) and air/water cleaning adapter kit is used to control the suction function of an endoscope during GI endoscopic procedures. The single use BioShield biopsy valve is used to cover the opening to the biopsy/suction channel of Olympus and G5 and newer Fujinon gastrointestinal endoscopes. The Torrent irrigation scope connector is used in conjunction with the Torrent irrigation tubing. The BioGuard air/water cleaning adapter is intended as part of the precleaning process to help clear the air/water channel of Olympus GI endoscopes post procedure.
US Endoscopy
00711787
In Commercial Distribution

  • 10724995180581 ()
  • 00724995180584 ()
00711787

  • Endoscope channel support kit
  • Endoscope working-channel valve, single-use
  • Endoscopic insufflation tubing set, single-use
The BioGuard valves (3-piece) and air/water cleaning adapter kit is used to control the suction function of an endoscope during GI endoscopic procedures. The single use BioShield biopsy valve is used to cover the opening to the biopsy/suction channel of Olympus and G5 and newer Fujinon gastrointestinal endoscopes. The BioGuard air/water cleaning adapter is intended as part of the precleaning process to help clear the air/water channel of Olympus GI endoscopes post procedure.
US Endoscopy
00711786
In Commercial Distribution

  • 10724995180574 ()
  • 00724995180577 ()
00711786

  • Endoscope channel support kit
  • Endoscope air/water valve, single-use
  • Endoscope working-channel valve, single-use
The BioGuard valves and air/water cleaning adapter kit is used to control the suction function of an endoscope during GI endoscopic procedures. The BioGuard air/water cleaning adapter is intended as part of the precleaning process to help clear the air/water channel of Olympus GI endoscopes post procedure.
US Endoscopy
00711785
In Commercial Distribution

  • 10724995180567 ()
  • 00724995180560 ()
00711785

  • Endoscope channel support kit
  • Endoscope air/water valve, single-use