SEARCH RESULTS FOR: (*bitcoin mining hardware comparison馃挷itenthusiasts.com馃挷Cryptocurrency*)(5684 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The USB-02 Dongle is the hardware key for Cardiospy software that makes possible the use of Cardiospy ECG Holter recorders (EC-2H, EC-3H or EC-12H) as a system and the management, procession and evaluation of the recorded row data. The universal analysis SW provides full disclosure ECG recordings on channels with a precise automatic QRS and PM detection, template and rhythm analysis, QRS classification, efficient ST, QT, AF, PM, HRV time and frequency based analysis with color coded display and printing with interactive modification possibilities in the automatic analysis in several languages. Export-import and archiving option of the recordings is available. The evaluation software works with a conventional PC- based computer under Win 2000/XP/VISTA , Windows 7, Windows 8, Windows 10 operating systems. The connection between the Holter and computer is performed by using Bluetooth and USB dongle. The Cardiospy analysis software provides ECG records of excellent quality.
LABTECH Kereskedelmi és Mérnöki Szolgáltató Korlátolt Felelősségű Társaság
USB-02 Dongle
In Commercial Distribution

  • 05999883490075 ()

  • Weight: 50 Gram
  • Width: 18.5 Millimeter
  • Width: 53 Millimeter
  • Length: 67.5 Millimeter
DEV-00USB-02

  • Electrocardiographic long-term ambulatory recording analyser
NKPW Psychophysiological biofeedback system A computerized device assembly designed for analysis and real-time feedback (biofeedback) of a variety of physiological parameters [e.g., heart rate, respiration, skin conductance, skin temperature, range of motion, force output, electroencephalography (EEG), electromyography (EMG), electrocardiography (ECG) data] to assist a patient in developing a degree of conscious control over typically involuntary functions, usually for relaxation training and muscle re-education. It includes multiple pieces of patient monitoring hardware (e.g., electrodes, sensors), computer interface devices, and dedicated software; it is intended to be used with an off-the-shelf computer. HJLM Biofeedback system application software An application software program designed for use in, or together with, a biofeedback system, so that it may function according to its intended purpose. This software program can be permanently installed, or exchanged as an upgrade. It may also be produced for installation in an off-the-shelf desktop or laptop computer.
Ochs Labs LLC
LW3
In Commercial Distribution

  • G253LW30 ()


  • Biofeedback system application software
The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system. A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.
MERIDIAN BIOSCIENCE, INC.
610210
In Commercial Distribution

  • 00840733102318 ()
610210

  • Thermal cycler nucleic acid amplification analyser IVD, laboratory
Vessel Analysis is a post-processing add-on module for ORS Visual that enables radiologists, cardiologists, vascular surgeons, and interventionalists to quickly and confidently evaluate CT angiographic studies. Vessel Analysis provides stenosis calculations, aneurysm quantification, and stent and stent-graft planning of the aorta, carotid, and renal arteries in an easy-to-use, intuitive screen that can simplify the clinical task of planning endovascular procedures. Advanced functionality such as automated vessel finding acts as a baseline for accurate vessel measurements and permits rapid segmentation of vessels. ORS Visual is a proprietary software application developed by Object Research Systems (ORS) Inc. that can be is used for the display and 3D visualization of medical image data derived from CT, MRI, and other modalities. It provides for the communication, storage, processing, rendering, and display of DICOM 3.0 compliant image data. ORS Visual, which is available in 32 and 64-bit versions, can be installed on a standard personal computer running the Windows operating system with the Microsoft ActiveX component and suitable graphics hardware.
Object Research Systems (ORS) Inc
ORS-VISU-VA01
In Commercial Distribution

  • B332VIVA0100 ()


  • Radiological PACS software
OsteoBoost is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, OsteoBoost resorbs and is later replaced by natural bone. It provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. OsteoBoost is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
OB-10P
In Commercial Distribution

  • 00816125023400 ()
OB-10P

  • Bone matrix implant, synthetic, non-antimicrobial
OsteoBoost is a bio-engineered mixture of calcium-based inorganic compounds. After it is implanted, OsteoBoost resorbs and is later replaced by natural bone. It provides a safe alternative to human or animal cadaver bone that completely eliminates the potential for disease transmission. OsteoBoost is an osteoconductive putty that is intended to be used to fill voids and gaps that are not intrinsic to the stability of the bone structure. These gaps or voids may be located in the extremities, spine, pelvis, or cranium. The putty may be shaped and pressed into the void by hand or inserted into a syringe and injected into the surgical site. The paste set in situ or ex situ provides a void filler that can augment hardware to support bone fragments during the surgical procedure. The set putty acts as a temporary support medium and is not intended to provide structural support during the healing process. The implant is radio-opaque. It is biocompatible and resorbs in the body as bone in-growth occurs.
BERKELEY ADVANCED BIOMATERIALS, LLC
OB-05P
In Commercial Distribution

  • 00816125023394 ()
OB-05P

  • Bone matrix implant, synthetic, non-antimicrobial
The NeuroSync EYE-SYNC device is a portable, fully enclosed eye tracking environment with two primary components: 1. Eye Tracker (head-mounted device) with eye tracking sensor and display 2. Android Tablet The eye tracker is a Pico Neo 3 Pro Eye with embedded sensors provided by Tobii Tech. It is mounted to the subject's face and held in place using a strap. The eye tracking sensor includes two cameras (one for each eye) to capture eye movement data. Eye gaze tracking is performed using a proprietary implementation of the pupil-corneal reaction method. The integrated display within the headset provides a binocular visual field and operates as part of the standalone VR system, running on Qualcomm Snapdragon XR2 hardware. The headset processes eye-tracking data internally and supports USB-C connectivity. The display receives eye tracking sensor information for post-processing, manages sensor calibration, provides binocular visual display to the subject, and interfaces with the Android tablet over Bluetooth. Eye gaze tracking and visual display is combined to provide several assessment paradigms to characterize subject eye tracking performance.
NEUROSYNC INC.
X03
In Commercial Distribution

  • 00860013612900 ()


  • Vision physiology/eye movement analysis system
  • Eye-tracking neurological/brain injury assessment device
5 cables in one bag with 10 pin yoked jumper cables green to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-018-005
In Commercial Distribution

  • 00856750007154 ()
PE-002-018-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables black to split ECG signals between two ECG devices is an accessory to the PURE EP System. The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-017-005
In Commercial Distribution

  • 00856750007116 ()
PE-002-017-005

  • Cardiac electrophysiology analysis system
5 cables in one bag with single jumper cables red to split ECG signals between two ECG devices is an accessory to the PURE EP System The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.
BIOSIG TECHNOLOGIES, INC.
PE-002-013-005
In Commercial Distribution

  • 00856750007093 ()
PE-002-013-005

  • Cardiac electrophysiology analysis system
< 1 ... 560 561 562 563 564 ... 569 >