SEARCH RESULTS FOR: (*Sandwhich Panel Machine*)(6101 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Youha, Bebebao, and Yiyadodo electric breast pumps are single-user, powered breast pump intended to be used by lactating women to express and collect milk from their breasts. THE ONE, YH-8012, BB-5020 and YY-5030 have both single (pumping from one breast) and double pumping (pumping from both breasts) configurations. YY-8011 and YH-8019 have a single pumping configuration only. A reciprocating diaphragm vacuum pump, driven by a microprocessor, generates the suction to extract the milk at vacuum levels up to 280 mmHg. The user interface for the THE ONE, YH-8012, BB-5020 and YY-5030 models consists of a front panel keypad and LCD display or LED display in which the user switches between modes and controls the vacuum pressure. The YY-5030 model does not have any visual indicators on the pump housing.
Ningbo Youhe Electrical Appliance Technology Co., Ltd
YH-8015
In Commercial Distribution

  • 16957031400044 ()
  • 06957031400047 ()


  • Breast pump, electric
The Youha, Bebebao, and Yiyadodo electric breast pumps are single-user, powered breast pump intended to be used by lactating women to express and collect milk from their breasts. THE ONE, YH-8012, BB-5020 and YY-5030 have both single (pumping from one breast) and double pumping (pumping from both breasts) configurations. YY-8011 and YH-8019 have a single pumping configuration only. A reciprocating diaphragm vacuum pump, driven by a microprocessor, generates the suction to extract the milk at vacuum levels up to 280 mmHg. The user interface for the THE ONE, YH-8012, BB-5020 and YY-5030 models consists of a front panel keypad and LCD display or LED display in which the user switches between modes and controls the vacuum pressure. The YY-5030 model does not have any visual indicators on the pump housing.
Ningbo Youhe Electrical Appliance Technology Co., Ltd
YH-8006IV
In Commercial Distribution

  • 16957031400037 ()
  • 06957031400030 ()


  • Breast pump, electric
The Youha, Bebebao, and Yiyadodo electric breast pumps are single-user, powered breast pump intended to be used by lactating women to express and collect milk from their breasts. THE ONE, YH-8012, BB-5020 and YY-5030 have both single (pumping from one breast) and double pumping (pumping from both breasts) configurations. YY-8011 and YH-8019 have a single pumping configuration only. A reciprocating diaphragm vacuum pump, driven by a microprocessor, generates the suction to extract the milk at vacuum levels up to 280 mmHg. The user interface for the THE ONE, YH-8012, BB-5020 and YY-5030 models consists of a front panel keypad and LCD display or LED display in which the user switches between modes and controls the vacuum pressure. The YY-5030 model does not have any visual indicators on the pump housing.
Ningbo Youhe Electrical Appliance Technology Co., Ltd
YH-8016
In Commercial Distribution

  • 16957031400020 ()
  • 06957031400023 ()


  • Breast pump, electric
The Youha, Bebebao, and Yiyadodo electric breast pumps are single-user, powered breast pump intended to be used by lactating women to express and collect milk from their breasts. THE ONE, YH-8012, BB-5020 and YY-5030 have both single (pumping from one breast) and double pumping (pumping from both breasts) configurations. YY-8011 and YH-8019 have a single pumping configuration only. A reciprocating diaphragm vacuum pump, driven by a microprocessor, generates the suction to extract the milk at vacuum levels up to 280 mmHg. The user interface for the THE ONE, YH-8012, BB-5020 and YY-5030 models consists of a front panel keypad and LCD display or LED display in which the user switches between modes and controls the vacuum pressure. The YY-5030 model does not have any visual indicators on the pump housing.
Ningbo Youhe Electrical Appliance Technology Co., Ltd
YH-8004
In Commercial Distribution

  • 16957031400013 ()
  • 06957031400016 ()


  • Breast pump, electric
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total bilirubin, total protein, blood urea nitrogen (BUN), and uric acid in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
ABAXIS, INC.
400-0029
In Commercial Distribution

  • EABA40000291 ()
  • EABA40000290 ()
400-0029

  • Total aspartate aminotransferase (AST) IVD, reagent
  • Glucose IVD, reagent
  • Total bilirubin IVD, reagent
  • Total protein IVD, reagent
  • Uric acid IVD, reagent
  • Creatinine IVD, reagent
  • Urea IVD, reagent
  • Alanine aminotransferase (ALT) IVD, reagent
  • Total alkaline phosphatase (ALP) IVD, reagent
  • Total amylase IVD, reagent
  • Calcium (Ca2+) IVD, reagent
  • Gamma-glutamyltransferase (GGT) IVD, reagent
  • Albumin IVD, reagent
Mains powered, infrared phototherapy device emitting up to 9 W at 980 nm. The LightForce PRO (LTC-900) is indicated for emitting energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for temporary relief of minor muscle and joint pain, muscle spasm, pain and stiffness associated with arthritis and promoting. relaxation of the muscle tissue and to temporarily increase local blood circulation. The PRO is a compact, portable medical laser therapy system. The laser light delivery system consists of a flexible optical fiber threaded through a lightweight hand piece. Activation occurs when the operator enables the laser and presses the finger switch. Depending on laser system configuration, the finger switch can function as an on/off switch. A touch-screen display panel allows the operator to adjust or set laser output level. The laser can operate in continuous wave mode or controlled pulse mode.
LITECURE LLC
LTC-900
In Commercial Distribution

  • 00854103007004 ()


  • Musculoskeletal infrared phototherapy unit, non-wearable
MDx-Chex for BCID2 is intended for use as an external positive and negative assayed control to monitor the performance of the qualitative detection of yeast, Gram positive and Gram negative bacteria, as well as associated antimicrobial resistance genes, by the BioFire® FilmArray® Blood Culture Identification 2 (BCID2) Panel on FilmArray® systems. Control 1 - GN: Gram negative bacteria: Acinetobacter colcoaceticus-baumannii complex, Bacteroides fragilis, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae group, Proteus spp., Salmonella spp., Serratia marcescens, Haemophilus influenza, Neisseria meningitides, Pseudomonas aeruginosa, Stenotrophomonas maltophilia; antimicrobial resistance genes: KPC, CTX-M, IMP, NDM, OXA-48-like, VIM, mcr-1. Control 2 - GPY: Gram positive bacteria: Enterococcus faecalis, Enterococcus faecium, Listeria monocytogenes, Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus lugdunesis, Streptococcus agalactiae, Streptococcus pneumonia, Streptococcus pyogenes; yeast: Candida albicans, Candida auris, Candida glabrata, Candida krusei, Candida parapsilosis, Candida tropicalis, Cryptococcus neoformans/gatti; antimicrobial resistance genes: mecA/C and MREJ, vanA/B. This product is not intended to replace manufacturer controls provided with the device.
STRECK, INC.
250065
In Commercial Distribution

  • 00844509002338 ()

  • Total Volume: 1.0 Milliliter
250065

  • Multiple-type bloodstream pathogen nucleic acid IVD, control
The Genadyne UNO is a single use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO NPWT Unit has a pre-determined lifespan. The unit features an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and offers selections of Continuous Mode at 80mmHg / 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Therapy Kits include a therapy unit, 70 cc canisters, USB charger, USB cable and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO could be provided separately. Dressing should be changed in line with standard wound dressing guidelines, typically every 3 days. More frequent changes may be required depending on level of exudate, condition of dressing, wound type/sizes, orientation of the dressing, environmental considerations or other patient considerations; e.g. when UNO is used on infected wounds.
GENADYNE BIOTECHNOLOGIES INC.
U-S2525-6
In Commercial Distribution

  • 00849405011699 ()


  • Negative-pressure wound therapy system, electric, single-use
The Genadyne UNO is a single use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO NPWT Unit has a pre-determined lifespan. The unit features an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and offers selections of Continuous Mode at 80mmHg / 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Therapy Kits include a therapy unit, 70 cc canisters, USB charger, USB cable and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO could be provided separately. Dressing should be changed in line with standard wound dressing guidelines, typically every 3 days. More frequent changes may be required depending on level of exudate, condition of dressing, wound type/sizes, orientation of the dressing, environmental considerations or other patient considerations; e.g. when UNO is used on infected wounds.
GENADYNE BIOTECHNOLOGIES INC.
U-S2025-6
In Commercial Distribution

  • 00849405011682 ()


  • Negative-pressure wound therapy system, electric, single-use
The Genadyne UNO is a single use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO NPWT Unit has a pre-determined lifespan. The unit features an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and offers selections of Continuous Mode at 80mmHg / 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Therapy Kits include a therapy unit, 70 cc canisters, USB charger, USB cable and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO could be provided separately. Dressing should be changed in line with standard wound dressing guidelines, typically every 3 days. More frequent changes may be required depending on level of exudate, condition of dressing, wound type/sizes, orientation of the dressing, environmental considerations or other patient considerations; e.g. when UNO is used on infected wounds.
GENADYNE BIOTECHNOLOGIES INC.
U-S2020-6
In Commercial Distribution

  • 00849405011675 ()


  • Negative-pressure wound therapy system, electric, single-use
< 1 ... 606 607 608 609 610 611 >