SEARCH RESULTS FOR: ("cryptocurrency meaning in bengali馃挷itenthusiasts.com馃挷Cryptocurrency")(1747890 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
The Non-Activated Clotting Test Kit contains the necessary components for an in vitro diagnostic test for use with the Sonoclot® Coagulation & Platelet Function Analyzer System. It may be used with native whole blood, citrated whole blood, and plasma.
The Non-Activated Kit may either be used as a non-activated clotting test or as a general use test with user provided activators. It is intended for customer designed hemostasis monitoring on the Sonoclot Analyzer. The Non-Activated cuvette allows for coagulation monitoring using tissue activation, thrombin activation, and other custom activators. Some of the applications for the Non-Activated test with the addition of customer determined reagents are monitoring of fibrin formation, fibrinolysis, hyperfibrinolysis and clot retraction.
When used with the Sonoclot Analyzer System, the Non-Activated test provides quantitative Onset/ACT and Clot Rate results as well as qualitative and quantitative information on the Sonoclot Signature including: fibrin formation, platelet function, and hyperfibrinolysis.
Each kit contains 100 lidded plastic cuvettes, 100 probes, and instructions for use. The cuvettes contain a magnetic stir bar.
SIENCO, INC.
800-0425
In Commercial Distribution
- B55880004250 ()
- B55880004251 ()
800-0425
- Multiple coagulation factor IVD, kit, clotting
The kACT Kit is an in vitro diagnostic test for use with the Sonoclot® Coagulation & Platelet Function Analyzer System. The kACT test is a kaolin activated whole blood clotting time test. It may also be used with citrated whole blood and plasma.
The kACT Kit is intended for high dose heparin management with or without aprotinin. The kACT test provides quantitative Onset/ACT and Clot Rate results with the Sonoclot Analyzer. The kACT test is not intended for platelet function monitoring.
Each kit contains 24 lidded blue plastic activation cuvettes, 24 probes, and instructions for use. The activation cuvettes contain a controlled amount of kaolin and a magnetic stir bar.
SIENCO, INC.
800-0401
In Commercial Distribution
- B55880004010 ()
- B55880004011 ()
800-0401
- Multiple coagulation factor IVD, kit, clotting
The kACT Kit is an in vitro diagnostic test for use with the Sonoclot Coagulation & Platelet Function Analyzer System. The kACT test is a kaolin activated whole blood clotting time test. It may also be used with citrated whole blood and plasma.
The kACT kit is intended for high dose heparin management with or without aprotinin. The kACT test provides quantitative Onset/ACT and Clot Rate results with the Sonoclot Analyzer. The kACT test is not intended for platelet function monitoring.
Each kACT Kit contains 100 lidded blue plastic activation cuvettes, 100 probes, and instructions for use. The activation cuvettes contain a controlled amount of kaolin and a magnetic stir bar.
SIENCO, INC.
800-0400
In Commercial Distribution
- B55880004001 ()
- B55880004000 ()
800-0400
- Multiple coagulation factor IVD, kit, clotting
No Description
Bio/Data Corporation
107153
In Commercial Distribution
- G0561071530 ()
107053
- Platelet aggregation analyser IVD
No Description
Bio/Data Corporation
102516
In Commercial Distribution
- G0561025161 ()
102516
- Lupus anticoagulant marker IVD, kit, clotting
No Description
Bio/Data Corporation
100994
In Commercial Distribution
- G0561009940 ()
100994
- Saline sodium citrate buffer IVD
No Description
Bio/Data Corporation
100991
In Commercial Distribution
- G0561009910 ()
100991
- Buffered isotonic saline reagent IVD
CITRATED: K, KH, RTH, FFH
HAEMONETICS CORPORATION
07-604-US
In Commercial Distribution
- 20812747018538 ()
- 10812747018531 ()
- Multiple coagulation factor IVD, reagent
Citrated: K, RT, FF
HAEMONETICS CORPORATION
07-605-US
In Commercial Distribution
- 20812747018460 ()
- 10812747018463 ()
- Multiple coagulation factor IVD, reagent
ELECTRONIC PIPPETTE KIT, 1000UL
HAEMONETICS CORPORATION
01-197
In Commercial Distribution
- 10812747018456 ()
- Total Volume: 1000 Microliter
- Coagulation analyser IVD, laboratory