SEARCH RESULTS FOR: (*Buy online Montana ID<网址:bzw985.com>太仓Università dell*)(8969 results)
The Surgimap® software assists healthcare professionals in viewing, storing, and measuring images as well as planning orthopedic surgeries. The device allows service providers to perform generic as well as specialty measurements of the images, and to plan surgical procedures. The device also includes tools for measuring anatomical components for placement of surgical implants, and offer online synchronization of the database with the possibility to share data among Surgimap® users. Clinical judgment and experience are required to properly use the software.
NEMARIS, INC
2.X
In Commercial Distribution
- 00859699006059 ()
- Patient health record information system
- Radiological PACS software
The Surgimap® software assists healthcare professionals in viewing, storing, and measuring images as well as planning orthopedic surgeries. The device allows service providers to perform generic as well as specialty measurements of the images, and to plan surgical procedures. The device also includes tools for measuring anatomical components for placement of surgical implants, and offer online synchronization of the database with the possibility to share data among Surgimap® users. Clinical judgment and experience are required to properly use the software.
NEMARIS, INC
2.2.9.X
In Commercial Distribution
- 00859699006042 ()
- Radiological PACS software
- Patient health record information system
BEQ-HMOD 70000-USA Adult Quadrox iD,
Softshell Venous Reser. 800ml,
Better Bladder 3/8,
BEQ-RF32 RotaFlow,
BC 60 plus,
Blood Microfilter System SQ 40 S,
Prebypass filter w/o Vent Porous Media 3/8x3/8,
Gas Filter,
Temperature Probe
DATASCOPE CORP.
BEQ-TOP 27610
Not in Commercial Distribution
- 00607567205642 ()
701065622
- Cardiopulmonary bypass system blood tubing set
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable.
Contains:
IT(BP2): Insertion Tube.
2x MTDWLN(BP)(BP7): microTargeting Electrode.
PT(BP2): Protective Tube.
Sterile Drape Sleeve for microTargeting motor
FC1020 Electrode Lead
Individual Specifications:
IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar).
MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L)
PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID
OD: 0.77mm
FHC, INC.
KTF1001-00133
Not in Commercial Distribution
- 00873263001332 ()
KTF1001
- Patient surgical drape, single-use
- Intracerebral cannula, implantable
- Depth electrode
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00890
In Commercial Distribution
- 00873263008904 ()
KTF1001
- Intracerebral cannula, nonimplantable, single-use
- Depth electrode
- Patient surgical drape, single-use
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable.
Contains:
IT(BP2): Insertion Tube.
2x MTDWLN(BP)(BP7): microTargeting Electrode.
PT(BP2): Protective Tube.
Sterile Drape Sleeve for microTargeting motor
FC1020 Electrode Lead
Individual Specifications:
IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar).
MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L)
PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID
OD: 0.77mm
FHC, INC.
KTF1001-00757
In Commercial Distribution
- 00873263007570 ()
KTF1001
- Depth electrode
- Patient surgical drape, single-use
- Intracerebral cannula, nonimplantable, single-use
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive.
Contains:
IT(AR16): Insertion Tube.
IT(AR17): Insertion Tube w/ Stylet.
MTDWLN(AR)(AR2): microTargeting Electrode.
66-CN-ET: Insertion Tube Extractor.
Individual Specifications:
IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID.
IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar).
MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00758
In Commercial Distribution
- 10873263007584 ()
- 00873263007587 ()
KTF1002
- Intracerebral cannula, nonimplantable, single-use
- Depth electrode
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00891
In Commercial Distribution
- 00873263008911 ()
- 10873263008918 ()
KTF1002
- Intracerebral cannula, nonimplantable, single-use
- Depth electrode
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive.
Contains:
IT(AR16): Insertion Tube.
IT(AR17): Insertion Tube w/ Stylet.
MTDWLN(AR)(AR2): microTargeting Electrode.
66-CN-ET: Insertion Tube Extractor.
Individual Specifications:
IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID.
IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar).
MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00134
Not in Commercial Distribution
- 10873263001346 ()
- 00873263001349 ()
KTF1002
- Intracerebral cannula, implantable
- Depth electrode
BEQ-HMOD 30000-USA Pediatric Quadrox iD, Softshell Venous Reser. 800ml, Better Bladder 1/4, BEQ-RF32 RotaFlow, BC 60 plus, Blood Microfilter System SQ 40 S, Prebypass filter w/o Vent Porous Media 3/8x3/8, Gas Filter, Pediatric Temp Probe
DATASCOPE CORP.
BEQ-TOP 27611
Not in Commercial Distribution
- 00607567205628 ()
701066061
- Cardiopulmonary bypass system blood tubing set