SEARCH RESULTS FOR: 保时捷msb平台→→1946.cc←←保时捷msb平台.wmka(9397 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Genadyne UNO is a single use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO NPWT Unit has a pre-determined lifespan. The unit features an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and offers selections of Continuous Mode at 80mmHg / 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Therapy Kits include a therapy unit, 70 cc canisters, USB charger, USB cable and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO could be provided separately. Dressing should be changed in line with standard wound dressing guidelines, typically every 3 days. More frequent changes may be required depending on level of exudate, condition of dressing, wound type/sizes, orientation of the dressing, environmental considerations or other patient considerations; e.g. when UNO is used on infected wounds.
GENADYNE BIOTECHNOLOGIES INC.
U-S1010-4
In Commercial Distribution

  • 00849405000549 ()


  • Negative-pressure wound therapy system, electric, single-use
The Genadyne UNO is a single use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO NPWT Unit has a pre-determined lifespan. The unit features an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and offers selections of Continuous Mode at 80mmHg / 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Therapy Kits include a therapy unit, 70 cc canisters, USB charger, USB cable and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO could be provided separately. Dressing should be changed in line with standard wound dressing guidelines, typically every 3 days. More frequent changes may be required depending on level of exudate, condition of dressing, wound type/sizes, orientation of the dressing, environmental considerations or other patient considerations; e.g. when UNO is used on infected wounds.
GENADYNE BIOTECHNOLOGIES INC.
U-S1010-5
In Commercial Distribution

  • 00849405000532 ()


  • Negative-pressure wound therapy system, electric, single-use
1. Description: ENDOCEM MTA was developed for regenerative endodontic treatment such as partial pulpotomy; and is designed to prevent irritation of pulp and secondary infections. It is a powder type. Use with saline or distilled water. The mixing ratio is 300 mg / 0.12 cc. 2. Principle of operation: ENDOCEM MTA is natural pure cement based endodontic material. product based on the science of pozzolan reactions. It has a fast setting time that allows for resin bonding to occur immediately after setting. It maintains its integrity in less than ideal clinical situations, including contamination with blood or saliva and presence of inflammation or infection. 3. Storage conditions: 1) The product shall be kept out of direct sunlight and stored at room temperature. It shall not be stored in a place with high temperature and humidity. 2) The remaining material shall be disposed of. 4. Shelf life: 3 years from manufacture date if storage conditions are followed.
MARUCHI
ENDOCEM MTA
In Commercial Distribution

  • 08800071200079 ()


  • Hygroscopic dental cement
Angiographic Convenience Kit, 6F
Oscor Inc.
ANG4-0442
In Commercial Distribution

  • 00885672103392 ()

  • Flow Rate: JR: 32 mL/sec, JL: 29 mL/sec, PT: 33 mL/sec
  • Recommended Pressure Limit: 1200 psi max.
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • Adelante Sigma Introducer, 6F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • JL 4.0/120 cm, JR 4.0/120 cm, Pigtail 145°/120 cm
  • Pigtail Side Holes: 5
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Maximum Recommended Guidewire 0.038 in
ANG4-0442

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 5F
Oscor Inc.
ANG4-0240
In Commercial Distribution

  • 00885672101916 ()

  • Recommended Pressure Limit: 1200 psi max.
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Maximum Recommended Guidewire 0.038 in
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • JL 4.0/110 cm, JR 4.0/110 cm, Pigtail 145°/120 cm
  • Adelante Sigma Introducer, 5F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Pigtail Side Holes: 5
  • Flow Rate: JR: 28 mL/sec, JL: 28 mL/sec, PT: 29 mL/sec
ANG4-0240

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 5F
Oscor Inc.
ANG4-0239
In Commercial Distribution

  • 00885672101909 ()

  • Adelante Sigma Introducer, 5F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Recommended Pressure Limit: 1200 psi max.
  • JL 4.0/110 cm, JR 4.0/110 cm, Straight Pigtail/120 cm
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • Flow Rate: JR: 28 mL/sec, JL: 28 mL/sec, PT: 30 mL/sec
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Pigtail Side Holes: 5
  • Maximum Recommended Guidewire 0.038 in
ANG4-0239

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 5F
Oscor Inc.
ANG4-0040
In Commercial Distribution

  • 00885672101893 ()

  • Adelante Sigma Introducer, 5F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Flow Rate: JR: 28 mL/sec, JL: 29 mL/sec, PT: 29 mL/sec
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Pigtail Side Holes: 5
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • Recommended Pressure Limit: 1200 psi max.
  • Maximum Recommended Guidewire 0.038 in
  • JL 4.0/100 cm, JR 4.0/100 cm, Pigtail 145°/110 cm
ANG4-0040

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 5F
Oscor Inc.
ANG4-0039
In Commercial Distribution

  • 00885672101886 ()

  • Maximum Recommended Guidewire 0.038 in
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • Adelante Sigma Introducer, 5F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Flow Rate: JR: 28 mL/sec, JL: 29 mL/sec, PT: 31 mL/sec
  • JL 4.0/100 cm, JR 4.0/100 cm, Straight Pigtail/110 cm
  • Pigtail Side Holes: 5
  • Recommended Pressure Limit: 1200 psi max.
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
ANG4-0039

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 4F
Oscor Inc.
ANG4-0238
Not in Commercial Distribution

  • 00885672101879 ()

  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Maximum Recommended Guidewire 0.038 in
  • Recommended Pressure Limit: 1200 psi max.
  • JL 4.0/110 cm, JR 4.0/110 cm, Pigtail 145°/120 cm
  • Adelante Sigma Introducer, 4F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Flow Rate: JR: 18 mL/sec, JL: 18 mL/sec, PT: 18 mL/sec
  • Pigtail Side Holes: 5
  • Guidewire - Length: 150 cm, OD: 0.035 in
ANG4-0238

  • Angiographic catheter, single-use
Angiographic Convenience Kit, 4F
Oscor Inc.
ANG4-0237
Not in Commercial Distribution

  • 00885672101862 ()

  • Flow Rate: JR: 18 mL/sec, JL: 18 mL/sec, PT: 19 mL/sec
  • Adelante Sigma Introducer, 4F, Length: 10 cm, Needle 18 G, Syringe 10 cc
  • Adelante Sigma Introducer Guidewire - Length: 50 cm, OD: 0.038 in
  • Maximum Recommended Guidewire 0.038 in
  • Guidewire - Length: 150 cm, OD: 0.035 in
  • JL 4.0/110 cm, JR 4.0/110 cm, Straight Pigtail/120 cm
  • Pigtail Side Holes: 5
  • Recommended Pressure Limit: 1200 psi max.
ANG4-0237

  • Angiographic catheter, single-use
< 1 ... 935 936 937 938 939 940 >