SEARCH RESULTS FOR: (*Imitation Ecole Nationale d*)(2922921 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A scan attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit. They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a scan slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp.
NIDEK CO.,LTD.
17466-0000
In Commercial Distribution
- 04987669100165 ()
- General/multiple surgical frequency-doubled solid-state laser system
The attachable delivery unit is attached to the Carl Zeiss 30SL/M (hereafter called Zeiss 30SL/M) to comprise a slit lamp delivery unit. The comprised scan slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. The attachable delivery unit is mainly comprised of a photocoagulation unit, a protective filter unit, and a split mirror illumination unit.
NIDEK CO.,LTD.
17465-0000
In Commercial Distribution
- 04987669100158 ()
- General/multiple surgical frequency-doubled solid-state laser system
The attachable delivery unit is attached to the Carl Zeiss Meditec SL 130 (hereafter called Zeiss SL 130) to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 to comprise a photocoagulation system.
The photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. The attachable delivery unit is mainly comprised of a photocoagulation unit, a protective filter unit, and a split mirror illumination unit.
NIDEK CO.,LTD.
17464-0000
In Commercial Distribution
- 04987669100141 ()
- General/multiple surgical frequency-doubled solid-state laser system
This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800/SL-1600. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body. A attachable delivery unit is mainly comprised of a photocoagulation unit and a protective filter unit.
They are attached to the NIDEK SL-1800/SL-1600 slit lamp for lasers to comprise a slit lamp delivery unit. The comprised slit lamp delivery unit is connected to the MC-500 to comprise a photocoagulation system. A photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp.
NIDEK CO.,LTD.
17462-0000
In Commercial Distribution
- 04987669100134 ()
- General/multiple surgical frequency-doubled solid-state laser system
This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body, to comprise the photocoagulation system and to treat affected areas using the slit lamp, Carl Zeiss Meditec 30 SL/M. This delivery unit is mainly comprised of the delivery unit, protective filter unit, and the split illumination mirror unit. This photocoagulation system allows the operator to select among photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and observation of the affected area with the slit lamp. This delivery unit can be attached only to the Carl Zeiss Meditec 30 SL/M.
NIDEK CO.,LTD.
17461-0000
In Commercial Distribution
- 04987669100127 ()
- General/multiple surgical frequency-doubled solid-state laser system
The Binocular Indirect Ophthalmoscope (hereafter called BIO) delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 (main body), to comprise the photocoagulation system and applied to the treatment of the affected area using the BIO delivery unit (HEINE OMEGA 500). The comprised photocoagulation system allows the operator to select between thermal photocoagulation with the multicolor laser beam (treatment beam) (wavelength: green (532 nm), yellow (577 nm), and red (647nm)) and observation with the BIO.
NIDEK CO.,LTD.
17379-0000
In Commercial Distribution
- 04987669100110 ()
- General/multiple surgical frequency-doubled solid-state laser system
This combination delivery unit is need to comprise the combination system which enables radiation of the red, yellow, or green laser beam or YAG laser beam while performing the observation with the slit lamp of the YAG laser system. This delivery unit is mounted on the slit lamp of the YAG laser system and connected to the NIDEK Multicolor Laser Photocoagulator MC-500 using the MC connecting cable and fiber optic cable. The combination system allows selection between photocoagulation with the red (647 nm), yellow (577 nm), or green (532 nm) laser beam and YAG laser beam (wavelength: 1064 nm (pulse laser)). In addition, they are selected easily by changing the optical path of the laser beam with the laser select
lever, and various kinds of safety devices are integrated into the system to make sure that only the selected laser beam is radiated. This combination delivery unit is the only delivery unit that can be connected both to the NIDEK Multicolor Laser Photocoagulator MC-500 and the NIDEK Ophthalmic YAG Laser System YC-1800.
NIDEK CO.,LTD.
17367-0000
In Commercial Distribution
- 04987669100103 ()
- General/multiple surgical frequency-doubled solid-state laser system
This delivery unit is connected to the NIDEK Multicolor Laser Photocoagulator, Model MC-500 main body to comprise the photocoagulation system and to treat affected areas using the slit lamp, NIDEK SL-1800. A slit lamp delivery unit that includes the SL-1800 comprises a photocoagulation system in connection with the MC-500 main body.
NIDEK CO.,LTD.
17481-0000
In Commercial Distribution
- 04987669100097 ()
- General/multiple surgical frequency-doubled solid-state laser system
The NIDEK Multicolor Laser Photocoagulator MC-500 is a laser photocoagulator for ophthalmology with the light source of wavelengths 647, 577, and 532 nm. As the conventional laser photocoagulators, the MC-500 can be used for retinal photocoagulation for treatment of ocular fundus diseases like diabetic retinopathy, age-related macular degeneration, retinopathy of prematurity, and retinal detachment, or for laser iridotomy and laser trabeculoplasty for treatment of glaucoma.
The device incorporates two types of lasers (diode-pumped solid state laser and laser diode) which enable efficient obtainment of laser beam oscillation of each wavelength. As the conventional device, various types of laser delivery units can be used. Therefore, transpupillary photocoagulation can be performed using various delivery units such as slit lamps and binocular indirect ophthalmoscope.
NIDEK CO.,LTD.
MC-500
In Commercial Distribution
- 04987669100080 ()
- General/multiple surgical frequency-doubled solid-state laser system
The ophthalmic YAG laser system YC-1800 emits Nd: YAG laser (hereafter called “YAG laser”) pulse beam by Q-switching. The YC-1800 allows the safe and bloodless treatment of intraocular diseases for outpatients by mechanical disruption caused by energy of the YAG laser pulses. The main purposes
of the YC-1800 are posterior capsulotomy for secondary cataract, iridotomy for acute angle-closure glaucoma, and for pupillary membranectomy for traction retinal detachment. The YC-1800 has a slit lamp for observation that includes the YAG laser and its controlling mechanism. The YC-1800 is also equipped with an operation panel and knobs that facilitate operation. The compact and lightweight power supply box is installed separately for lightness and compactness of the system. In addition, a motorized table for the YC-1800 is available optionally.
NIDEK CO.,LTD.
YC-1800
In Commercial Distribution
- 04987669100073 ()
- Ophthalmic solid-state laser system, photodisruption