The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
2.5x12mm
In Commercial Distribution
- 00195451000003 ()
- Balloon Length: 12 Millimeter
- Balloon Diameter: 2.5 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.044 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL2512
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
3.0x12mm
In Commercial Distribution
- 00195451000010 ()
- Balloon Length: 12 Centimeter
- Balloon Diameter: 3.0 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.045 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL3012
- Intravascular lithotripsy system balloon catheter, coronary
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145065V2
In Commercial Distribution
- 4042301159984 ()
- 04042301159977 ()
- 6 x 5
145065V2
- Cardiac defect occluder
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145054V2
In Commercial Distribution
- 4042301159960 ()
- 04042301159953 ()
- 5 x 4
- Cardiac defect occluder
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145044V2
In Commercial Distribution
- 04042301159939 ()
- 4042301159946 ()
- 4 x 4
145044V2
- Cardiac defect occluder
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145116V2
In Commercial Distribution
- 4042301160041 ()
- 04042301160034 ()
- 11 x 6
145116V2
- Cardiac defect occluder
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145096V2
In Commercial Distribution
- 4042301160027 ()
- 04042301160010 ()
- 9 x 6
145096V2
- Cardiac defect occluder
Nit-Occlud® PDA is a system for transcatheter occlusion of Patent Ductus Arteriosus (PDA) with spiral coils. The system consists of a spiral coil mounted in a straightened fashion on a flexible delivery system including a disposable handle. The Nit-Occlud® PDA has a cone in cone configuration which results from the fact that the proximal windings of the coil are wound the reverse direction. Nit-Occlud® PDA is available as Flexible and Medium Type. The flexible and medium types are pre-loaded into the transportation sheath.
pfm medical ag
145076V2
In Commercial Distribution
- 4042301160003 ()
- 04042301159991 ()
- 7 x 6
145076V2
- Cardiac defect occluder
The Occlutech Pistol Pusher is a medical device compatible with the Occlutech Atrial Septal Defect Occluder (Occlutech ASD Occluder) and applications with special cardiac catheters in the human heart.The Occlutech Pistol Pusher is composed of proximal body and distal parts. The distal part consists of titanium alloy jaws and a stainless-steel container while the body part is polymer laminated stainless steel coil. The proximal parts of the Occlutech Pistol Pusher largely contains plastic components. The jaws and container mechanism grab and secure the ball connector of the compatible Occlutech ASD Occluder and allow retraction of the Occlutech ASD Occluder into the ODS III and advancement to the implant area. The proximal part has a trigger for releasing the compatible Occlutech ASD Occluder and a locking mechanism for locking the system to prevent unintentional release. The Occlutech Pistol Pusher is available in different sizes for compatibility with the Occlutech ASD Occluders.
OCCLUTECH TIBBI URUNLER SANAYI VE TICARET LIMITED SIRKETI
38PP210
In Commercial Distribution
- 08683463400222 ()
- Outer Diameter: 3.23 Millimeter
- Length: 120 Centimeter
38PP210
- Cardiac defect occluder
The Occlutech Pistol Pusher is a medical device compatible with the Occlutech Atrial Septal Defect Occluder (Occlutech ASD Occluder) and applications with special cardiac catheters in the human heart.The Occlutech Pistol Pusher is composed of proximal body and distal parts. The distal part consists of titanium alloy jaws and a stainless-steel container while the body part is polymer laminated stainless steel coil. The proximal parts of the Occlutech Pistol Pusher largely contains plastic components. The jaws and container mechanism grab and secure the ball connector of the compatible Occlutech ASD Occluder and allow retraction of the Occlutech ASD Occluder into the ODS III and advancement to the implant area. The proximal part has a trigger for releasing the compatible Occlutech ASD Occluder and a locking mechanism for locking the system to prevent unintentional release. The Occlutech Pistol Pusher is available in different sizes for compatibility with the Occlutech ASD Occluders.
OCCLUTECH TIBBI URUNLER SANAYI VE TICARET LIMITED SIRKETI
38PP185
In Commercial Distribution
- 08683463400208 ()
- Outer Diameter: 2.93 Millimeter
- Length: 120 Centimeter
38PP185
- Cardiac defect occluder