SEARCH RESULTS FOR: (*EPS Shape Moulding Machine*)(3554 results)
The bioBLOCK Subtalar Implant consists of a soft-threaded implant, designed to be inserted between the posterior and middle facets of the subtalar joint, trial implant and the corresponding instrumentation to facilitate insertion. The implant is cylindrical in shape and incorporates a center cannula designed for use with a guide wire to facilitate proper placement. The implant is indicated as an internal support in the treatment of flat foot, providing structural support.
Ascension Orthopedics, Inc.
040008
In Commercial Distribution
- M2480400080 ()
- 10381780066552 ()
- 8 mm dia x 15 mm L
040008
- Subtalar implant, non-bioabsorbable
The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered. The Final Fit software has two major functions: 1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000 2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data)
NIDEK CO.,LTD.
1.13
In Commercial Distribution
- 04987669101346 ()
- Ophthalmic excimer laser system
The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered.
The Final Fit software has two major functions:
1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000
2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data)
NIDEK CO.,LTD.
1.12
In Commercial Distribution
- 04987669100042 ()
- Ophthalmic excimer laser system
The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered.
The Final Fit software has two major functions:
1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000
2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data)
NIDEK CO.,LTD.
1.11US
In Commercial Distribution
- 04987669100035 ()
- Ophthalmic excimer laser system