SEARCH RESULTS FOR: ("Make Dominican School of Philosophy")(70001 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
The Occlutech Pistol Pusher is a medical device compatible with the Occlutech Atrial Septal Defect Occluder (Occlutech ASD Occluder) and applications with special cardiac catheters in the human heart.The Occlutech Pistol Pusher is composed of proximal body and distal parts. The distal part consists of titanium alloy jaws and a stainless-steel container while the body part is polymer laminated stainless steel coil. The proximal parts of the Occlutech Pistol Pusher largely contains plastic components. The jaws and container mechanism grab and secure the ball connector of the compatible Occlutech ASD Occluder and allow retraction of the Occlutech ASD Occluder into the ODS III and advancement to the implant area. The proximal part has a trigger for releasing the compatible Occlutech ASD Occluder and a locking mechanism for locking the system to prevent unintentional release. The Occlutech Pistol Pusher is available in different sizes for compatibility with the Occlutech ASD Occluders.
OCCLUTECH TIBBI URUNLER SANAYI VE TICARET LIMITED SIRKETI
38PP165
In Commercial Distribution
- 08683463400185 ()
- Outer Diameter: 2.73 Millimeter
- Length: 120 Centimeter
38PP165
- Cardiac defect occluder
The Occlutech Pistol Pusher is a medical device compatible with the Occlutech Atrial Septal Defect Occluder (Occlutech ASD Occluder) and applications with special cardiac catheters in the human heart.The Occlutech Pistol Pusher is composed of proximal body and distal parts. The distal part consists of titanium alloy jaws and a stainless-steel container while the body part is polymer laminated stainless steel coil. The proximal parts of the Occlutech Pistol Pusher largely contains plastic components. The jaws and container mechanism grab and secure the ball connector of the compatible Occlutech ASD Occluder and allow retraction of the Occlutech ASD Occluder into the ODS III and advancement to the implant area. The proximal part has a trigger for releasing the compatible Occlutech ASD Occluder and a locking mechanism for locking the system to prevent unintentional release. The Occlutech Pistol Pusher is available in different sizes for compatibility with the Occlutech ASD Occluders.
OCCLUTECH TIBBI URUNLER SANAYI VE TICARET LIMITED SIRKETI
38PP125
In Commercial Distribution
- 08683463400161 ()
- Outer Diameter: 2.13 Millimeter
- Length: 120 Centimeter
38PP125
- Cardiac defect occluder
The VASCADE VCS is intended to seal femoral vessel puncture sites at the completion of catheter-based procedures. The system is designed to deliver a resorbable Collagen Patch, extra-vascularly, at the vessel puncture site to achieve hemostasis. For use in 6F & 7F introducer sheaths; overall length of the sheath (including the hub) needs to be less than 15cm.
CARDIVA MEDICAL, INC.
700-580I
In Commercial Distribution
- M729700580I1 ()
- M729700580I0 ()
- M729700580I3 ()
- Catheter Gauge: 7 French
- Catheter Gauge: 6 French
- Femoral artery closure plug/patch, collagen
The VASCADE VCS is intended to seal femoral vessel puncture sites at the completion of catheter-based procedures. The system is designed to deliver a resorbable Collagen Patch, extra-vascularly, at the vessel puncture site to achieve hemostasis. For use in 5F introducer sheaths; overall length of the sheath (including the hub) needs to be less than 15cm.
CARDIVA MEDICAL, INC.
700-500DX
In Commercial Distribution
- M729700500DX1 ()
- M729700500DX0 ()
- M729700500DX3 ()
- Catheter Gauge: 5 French
- Femoral artery closure plug/patch, collagen
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-003
In Commercial Distribution
- 10810098650295 ()
4340
- Implantable sleep apnoea treatment system, respiration-sensing
The MARGINPROBE System is an adjunctive diagnostic tool for identification of cancerous tissue at the margins (less than 1mm) of the main ex-vivo lumpectomy specimen following primary excision and is indicated for intraoperative use, in conjunction with standard methods (such as intraoperative imaging and palpation) in patients undergoing breast lumpectomy surgery for previously diagnosed breast cancer.
DILON MEDICAL TECHNOLOGIES LTD
SA0590020
In Commercial Distribution
- 07290012534058 ()
- Intraoperative tumour margin analysis probe
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-001
Not in Commercial Distribution
- 00855728005796 ()
4340
- Implantable sleep apnoea treatment system, respiration-sensing
The Inspire® Stimulation Lead (Model 4063) is designed to deliver stimulation to the hypoglossal nerve for the treatment of obstructive sleep apnea. The lead features a flexible, self-sizing cuff. Electrodes in the inner surface of the cuff deliver stimulation to the nerve. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG).
Inspire Medical Systems, Inc.
900-013-001
In Commercial Distribution
- 10855728005793 ()
4340
- Implantable sleep apnoea treatment system, respiration-sensing
SW APP A90300 RECHAGER APPLICATION
MEDTRONIC, INC.
A90300
In Commercial Distribution
- 00763000275655 ()
- Multiple active implantable device programmer
SOLESTA® is indicated for the treatment of fecal incontinence in patients 18 years and older who have failed conservative therapy (eg. diet, fiber therapy, anti-motility medications).
SALIX PHARMACEUTICALS, LTD.
1085003
In Commercial Distribution
- 00365649850035 ()
- 10365649850032 ()
- Anal tissue reconstructive material