SEARCH RESULTS FOR: ("cryptocurrency meaning in bengali馃挷itenthusiasts.com馃挷Cryptocurrency")(59449 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Anti-HBs EIA, Positive Control 1.5 mL
Bio-RAD Laboratories, Inc.
26152
In Commercial Distribution
- 00847865002073 ()
- Total Volume: 1.5 Milliliter
26152
- Hepatitis B virus surface total antibody IVD, reagent
Anti-HBs EIA Hepatitis B Surface Antigen (Human) Horeseradish Peroxidase Conjugate
Bio-RAD Laboratories, Inc.
26151
In Commercial Distribution
- 00847865002066 ()
- Total Volume: 3 Milliliter
26151
- Hepatitis B virus surface total antibody IVD, reagent
Alinity i Anti-HBs Reagent Kit (1200T)
Abbott Ireland Diagnostics
07P8857
In Commercial Distribution
- 00380740173562 ()
07P8857
- Hepatitis B virus surface total antibody IVD, reagent
Alinity i Anti-HBs Reagent Kit (200T)
Abbott Ireland Diagnostics
07P8852
In Commercial Distribution
- 00380740173555 ()
07P8852
- Hepatitis B virus surface total antibody IVD, reagent
ARCHITECT AUSAB Reagent Kit (500T)
Abbott Ireland Diagnostics
01L8238
In Commercial Distribution
- 00380740171759 ()
01L8238
- Hepatitis B virus surface total antibody IVD, reagent
ARCHITECT AUSAB Reagent Kit (100T)
Abbott Ireland Diagnostics
01L8228
In Commercial Distribution
- 00380740171742 ()
01L8228
- Hepatitis B virus surface total antibody IVD, reagent
Anti-HBs EIA, Conjugate Diluent 15 mL
Bio-RAD Laboratories, Inc.
26155
In Commercial Distribution
- 00847865002103 ()
- Total Volume: 15 Milliliter
26155
- Hepatitis B virus surface total antibody IVD, reagent
The Cordella Pulmonary Artery Sensor System is designed for on-demand measurement of pulmonary artery pressure from the patient’s home. Cordella Sensor Delivery Kit consists of the Cordella PA Sensor and Delivery System which are components of the Cordella Pulmonary Artery Sensor System.
Cordella PA Sensor
The Cordella Sensor is a small implant that resides permanently in the patient’s right pulmonary artery. The Cordella Sensor does not contain batteries or active electrical components. The Cordella Sensor is not made with natural rubber latex.
Delivery System
The Delivery System is a catheter with a pre-loaded Cordella Sensor at the distal end and is used to implant the Cordella Sensor into the right pulmonary artery. The Delivery System comprises a stability sheath, torque catheter, handle, torque luer, and side port. Implantation of the Cordella Sensor using the Delivery System is designed to be performed during right heart catheterization through venous access. The Stability Sheath contains a marker band at the distal end to aid in visualization under fluoroscopy. The Delivery System is not made with natural rubber latex.
Endotronix, Inc.
100303-05
In Commercial Distribution
- 00850008997006 ()
- Implantable pulmonary artery pressure monitoring system
The EXOGEN device provides non-invasive therapy for healing non-unions and accelerating time to healing of fresh fractures. The EXOGEN Ultrasound Bone Healing Systems has been designed both for use with conservatively treated fresh fractures and non-unions or surgically treated non-unions. The device transmits a low intensity ultrasound signal to the fracture site through coupling gel, with little or no sensation felt by the patient during the treatment. The low-intensity pulsed ultrasound has been shown in in-vitro and in-vivo studies to stimulate cells to produce growth factors and proteins that are important to bone healing. The patient administers treatment at home or at work, once daily, for 20 minutes, or as prescribed by a physician. The device automatically alerts the patient in case of improper application or device performance. The EXOGEN Ultrasound Bone Healing System consists of one main operating unit, gel bottles and strap. The main operating unit provides the treatment control circuitry, the primary battery supply, and monitors the operation of the transducer at the fracture site. The signal specifications cannot be changed.
BIOVENTUS LLC
71034600
In Commercial Distribution
- M937710346001 ()
71034600
- Bone growth ultrasonic stimulator
- Radiographic image marker, manual
- Skin topical coupling gel
- Personal device holder, single-use
No Description
Edwards Lifesciences LLC
4300
In Commercial Distribution
- 00690103021851 ()
- CONDUIT SIZE 30 MM, VALVE SIZE 31 MM
430030MM
- Aortic open-surgery heart valve bioprosthesis/synthetic polymer aorta graft