SEARCH RESULTS FOR: 什么烟让人闻了听话(打开网站:maiyao88.com)喷雾5秒昏睡货到付款哪里找93539(9102 results)
PUMP MMT-1715KL 630G V2.8 BK SF MG
MEDTRONIC MINIMED, INC.
MMT-1715KL
In Commercial Distribution
- 00763000072520 ()
- Ambulatory insulin infusion pump, electronic, software-dosing, binary algorithm
PUMP MMT-1780KPK 670G V4.10 EN MG
MEDTRONIC MINIMED, INC.
MMT-1780KPK
In Commercial Distribution
- 00763000090203 ()
- Ambulatory insulin infusion pump, electronic, software-dosing, scalar algorithm
KIT MMT-1755K 630G 3ML V4.10 BK EN
MEDTRONIC MINIMED, INC.
MMT-1755K
In Commercial Distribution
- 00763000101527 ()
- Ambulatory insulin infusion pump, electronic, software-dosing, binary algorithm
KIT MMT-1760KPK 670G V4.10 EN MG
MEDTRONIC MINIMED, INC.
MMT-1760KPK
In Commercial Distribution
- 00763000096984 ()
- Ambulatory insulin infusion pump, electronic, software-dosing, scalar algorithm
PUMP MMT-1715K 630G V4.10 BK SF MG
MEDTRONIC MINIMED, INC.
MMT-1715K
In Commercial Distribution
- 00763000090197 ()
- Ambulatory insulin infusion pump, electronic, software-dosing, binary algorithm
DDU-100 Lifeline AED, US, English, 1 set Adult Pads (DDP-100), Quick Start Card (DAC-501), Op. Guide (DAC-A581-EN), 5 year battery pack with 9V Lithium battery (DCF-200), prescription activation form
DEFIBTECH, L.L.C.
DCF-A100RX-EN
In Commercial Distribution
- 00815098020737 ()
- Non-rechargeable public semi-automated external defibrillator
The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
3.0x12mm
In Commercial Distribution
- 00195451000010 ()
- Balloon Length: 12 Centimeter
- Balloon Diameter: 3.0 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.045 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL3012
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
2.5x12mm
In Commercial Distribution
- 00195451000003 ()
- Balloon Length: 12 Millimeter
- Balloon Diameter: 2.5 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.044 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL2512
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
4.0x12mm
In Commercial Distribution
- 00195451000034 ()
- Balloon Length: 12 Millimeter
- Balloon Diameter: 4.0 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.047 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL4012
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2+ Coronary IVL Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenoses that are anticipated to exhibit resistance to full balloon dilatation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2+ Coronary IVL Catheter is available in four (4) sizes: 2.5x12 mm, 3.0x12 mm, 3.5x12 mm, and 4.0x12 mm. The Shockwave C2+ is compatible with a 5F guiding catheter and extensions, has a working length of 138 cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
3.5x12mm
In Commercial Distribution
- 00195451000027 ()
- Balloon Length: 12 Millimeter
- Balloon Diameter: 3.5 Millimeter
- Balloon Proximal Outer Diameter (OD): 0.045 Inch
- Length: 138 Centimeter
- Guidewire Compatibility: 5 French
C2PIVL3512
- Intravascular lithotripsy system balloon catheter, coronary