SEARCH RESULTS FOR: 新茶直播(下载网址:K782.com).5mi587t9.x视频(打开网站:K782.com).m16t(4944 results)
Anchor
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
SC-4319
In Commercial Distribution
- 08714729905325 ()
- Analgesic spinal cord electrical stimulation system
Surgical Lead Kit
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
SC-8452-70
In Commercial Distribution
- 08714729995845 ()
- Length: 70 Centimeter
- Implantable electrical stimulation system intraoperative test lead
Surgical Lead Kit
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
SC-8452-50
In Commercial Distribution
- 08714729995838 ()
- Length: 50 Centimeter
- Implantable electrical stimulation system intraoperative test lead
No Description
Edwards Lifesciences LLC
9120AS26A
In Commercial Distribution
- 00690103191936 ()
- 26 MILIMETER DIAMETER NOMINAL BALLOON DIAMETER
9120AS26A
- Cardiac valvuloplasty catheter
No Description
Edwards Lifesciences LLC
9120AS23A
In Commercial Distribution
- 00690103191929 ()
- 23 MILIMETER DIAMETER NOMINAL BALLOON DIAMETER
9120AS23A
- Cardiac valvuloplasty catheter
No Description
Edwards Lifesciences LLC
9120FS26
In Commercial Distribution
- 00690103181999 ()
- 26 MILIMETER DIAMETER NOMINAL BALLOON DIAMETER
9120FS26
- Catheter introducer
No Description
Edwards Lifesciences LLC
9120FS23
In Commercial Distribution
- 00690103181982 ()
- 23 MILIMETER DIAMETER NOMINAL BALLOON DIAMETER
9120FS23
- Catheter introducer
The Shockwave C2 Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenosis that are anticipated to exhibit resistance to full balloon dilation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2 Catheter is available in four (4) sizes: 2.5x12mm, 3.0x12mm, 3.5x12mm, and 4.0x12mm. The Shockwave C2 is compatible with a 6F guiding catheter and extensions, has a working length of 138cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
3.5 x 12mm
In Commercial Distribution
- 00195451000102 ()
- Balloon Proximal Outer Diameter (OD): 0.045 Inch
- Balloon Diameter: 3.5 Millimeter
- Balloon Length: 12 Millimeter
- Catheter Working Length: 138 Centimeter
- Introducer Sheath Compatibility: 6 French
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
C2IVL3512
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2 Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenosis that are anticipated to exhibit resistance to full balloon dilation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2 Catheter is available in four (4) sizes: 2.5x12mm, 3.0x12mm, 3.5x12mm, and 4.0x12mm. The Shockwave C2 is compatible with a 6F guiding catheter and extensions, has a working length of 138cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
3.0 x 12mm
In Commercial Distribution
- 00195451000096 ()
- Balloon Diameter: 3.0 Millimeter
- Balloon Length: 12 Millimeter
- Catheter Working Length: 138 Centimeter
- Introducer Sheath Compatibility: 6 French
- Balloon Proximal Outer Diameter (OD): 0.045 Inch
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
C2IVL3012
- Intravascular lithotripsy system balloon catheter, coronary
The Shockwave C2 Catheter is a proprietary lithotripsy device delivered through the coronary arterial system of the heart to the site of an otherwise difficult to treat calcified stenosis, including calcified stenosis that are anticipated to exhibit resistance to full balloon dilation or subsequent uniform coronary stent expansion. The IVL Catheter contains integrated lithotripsy emitters for the localized delivery of acoustic pressure pulse therapy. The lithotripsy technology generates acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion allowing subsequent dilatation of a coronary artery stenosis using low balloon pressure. The system consists of the IVL Catheter, IVL Connector Cable and IVL Generator. The Shockwave C2 Catheter is available in four (4) sizes: 2.5x12mm, 3.0x12mm, 3.5x12mm, and 4.0x12mm. The Shockwave C2 is compatible with a 6F guiding catheter and extensions, has a working length of 138cm, and shaft depth markers at the proximal end. The catheter is coated with hydrophilic coating to 22.75 cm from the distal tip to reduce friction during device delivery.
Shockwave Medical, Inc.
2.5 x 12mm
In Commercial Distribution
- 00195451000089 ()
- Balloon Proximal Outer Diameter (OD): 0.044 Inch
- Balloon Diameter: 2.5 Millimeter
- Balloon Length: 12 Millimeter
- Catheter Working Length: 138 Centimeter
- Introducer Sheath Compatibility: 6 French
- Guidewire Diameter: 0.014 Inch
- Balloon Nominal (Inflation) Pressure: 6 Atmosphere
- Balloon Rated Burst Pressure: 10 Atmosphere
C2IVL2512