The Model 2740 physician programmer is designed for use by a physician to non invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short range radio frequency (RF) telemetry, telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-116
In Commercial Distribution
- 00810098650151 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The sleep remote is an external device that is about the size of a cell phone and is used by the patient to activate the Inspire system before they go to sleep. The patient places the remote over the implanted IPG site, and uses push buttons on top of the programmer to: a.) turn the therapy ON or OFF, b.) temporarily suspend therapy, or c.) make adjustments to the stimulation strength (within limits set by the physician). The patient’s sleep remote also allows patients to check the status of the IPG battery. There are both visual and audio indicators that provide information on the IPG status (therapy ON/OFF, therapy paused, stimulation level and battery status). The Inspire sleep remote will only communicate with the Inspire IPG.
Inspire Medical Systems, Inc.
900-017-003
In Commercial Distribution
- 00810098650083 ()
2580
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740S SleepSync Programmer Application is a standalone software that is downloaded and installed on a user-owned computer and paired by the user (clinician) with the Model 2740C Programmer Cable to non-invasively interrogate and program the Implantable Pulse Generator (IPG) of the Inspire Upper Airway Stimulation (UAS) System. The SleepSync Programmer Application provides the graphic user interface (GUI) for the SleepSync Programmer System (Model 2740S and Model 2740C) while the Programmer Cable provides the communications interface between the SleepSync Programmer Application and the IPG. The SleepSync Programmer Application has the capability to monitor respiratory waveforms, program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-029-001
In Commercial Distribution
- 00810098650038 ()
2740S
- Implantable sleep apnoea treatment system, respiration-sensing
The sleep remote is an external device that is about the size of a cell phone and is used by the patient to activate the Inspire system before they go to sleep. The patient places the remote over the implanted IPG site, and uses push buttons on top of the programmer to: a.) turn the therapy ON or OFF, b.) temporarily suspend therapy, or c.) make adjustments to the stimulation strength (within limits set by the physician). The patient’s sleep remote also allows patients to check the status of the IPG battery. There are both visual and audio indicators that provide information on the IPG status (therapy ON/OFF, therapy paused, stimulation level and battery status). The Inspire sleep remote will only communicate with the Inspire IPG.
Inspire Medical Systems, Inc.
900-017-0051
In Commercial Distribution
- 00810098650014 ()
2580
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short range radio frequency (RF) telemetry, telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-115
In Commercial Distribution
- 00810098650007 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
Right Mandibular Component
TMJ Solutions, Inc.
YYMMDDNNNNRM
In Commercial Distribution
- B004YYMMDDNNNNRM0 ()
- Total temporomandibular joint prosthesis
Right Fossa Component
TMJ Solutions, Inc.
YYMMDDNNNNRF
In Commercial Distribution
- B004YYMMDDNNNNRF0 ()
- Total temporomandibular joint prosthesis
Left Mandibular Component
TMJ Solutions, Inc.
YYMMDDNNNNLM
In Commercial Distribution
- B004YYMMDDNNNNLM0 ()
- Total temporomandibular joint prosthesis
Left Fossa Component
TMJ Solutions, Inc.
YYMMDDNNNNLF
In Commercial Distribution
- B004YYMMDDNNNNLF0 ()
- Total temporomandibular joint prosthesis
Flow Diverter System
Stryker Corporation
FDSE45035
In Commercial Distribution
- 07613327587852 ()
- Length: 35.0 Millimeter
- Lumen/Inner Diameter: 4.5 Millimeter
FDSE45035
- Bare-metal intracranial vascular stent